Laserfiche WebLink
t <br /> MONITORING SYSTEM CERTIFIATION ec&," <br /> For Use By All.Jurisdictions Within the State of California <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16, Division 3, Title 23, California C e u on VE <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must e p o <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system o'A'ner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. APR 17 2015 <br /> A. General Information ENVIRONMENTAL <br /> Facility Name: Shell Bldr(V FU nt-_ono°'IA#ClklT <br /> Site Address: 16500 S. Harlan Road City: Lathrop,CA Zip: 95330 <br /> Facility Contact Person: Nick Arbabian Contact Phone No.: (209) 983-0381 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 02/24/2015 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicatespecific equipment inspected/serviced: <br /> Tank ID: #1 Regular 12000 Gal Tank ID: #2 Premium 12000 Gal <br /> ®In-Tank Gauging Probe. Model: MAGA ®In-Tank Gauging Probe. Model: MAGA <br /> ®Annular Space or Vault Sensor. Model: 794380-407 ®Annular Space or Vault Sensor. Model: 794380-407 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 Z Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> M Mechanical Line Leak Detector. Model: Vaporless 99LD2000 ®Mechanical Line Leak Detector. Model: Vaporless 99LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑In=Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑ Mechanical Line Leak Detector. Model <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). j ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> Z Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ® Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s)- Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑ Dispenser Containment I-loat(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers-copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br /> attached a copy of the report; (check all that applr): ® System set-up ® Alarm history report <br /> Technician Name(print): Nikola Zagorov Sig(nature: �4 C?p t•! <br /> Certification No.: Veeder Root Level 4#A32784 License.No.: 958763 A <br /> Testing Company Name: ECO-CHEK Compliance, Inc. Phone No.: (888) 500-CHEK <br /> Testing Company Address: P.O. Box 1394, Lafayette, CA 94549 Date of Testina/Servicing: 02/24/2015 <br /> Page 1 of 4 <br /> Rev(2/08) <br />