My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 3:19:01 PM
Creation date
6/3/2020 9:50:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING SYSTEM CERTIFICATION ece� <br /> For Use By All Jurisdictions Within the State of California ECO CKK 0".1—cr <br /> Authority Cited: Chapter 6.7, Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. A separate certification or report must be prepared for each <br /> monitoring system control panel by the technician who performs the work. A copy of this form must be provided to the tank system owner/operator. <br /> The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A. General Information <br /> Facility Name: Shell Bldg.No.: <br /> Site Address: 16500 S. Harlan Road City: Lathrop,CA Zip: 95330 <br /> Facility Contact Person: Chris Arbabian Contact Phone No.: (209) 983-0381 <br /> Make/Model of Monitoring System: Veeder Root TLS 350 Date of Testing/Servicing: 02/27/2018 <br /> B. Inventory of Equipment Tested/Certified <br /> Check the a ro riate boxes to indicatespecific a ui ment inspected/serviced: <br /> Tank ID: #1 Regular 12000 Gal Tank ID: #2 Premium 12000 Gal <br /> ®In-Tank Gauging Probe. Model: MAGA ®In-Tank Gauging Probe. Model: MAGA <br /> ®Annular Space or Vault Sensor. Model: 794380-409 ®Annular Space or Vault Sensor. Model: 794380-409 <br /> ®Piping Sump/Trench Sensor(s). Model: 794380-208 ®Piping Sump/Trench Sensor(s). Model: 794380-208 <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ®Mechanical Line Leak Detector. Model: Vaporless 99LD2000 ®Mechanical Line Leak Detector. Model: V_aporless 99LD2000 <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> ❑In-Tank Gauging Probe. Model: ❑In-Tank Gauging Probe. Model: <br /> ❑Annular Space or Vault Sensor. Model: ❑Annular Space or Vault Sensor. Model: <br /> ❑Piping Sump/Trench Sensor(s). Model: ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ❑Tank Overfill/High-Level Sensor. Model: ❑Tank Overfill/High-Level Sensor. Model: <br /> ❑Other(specify equipment type and model in Section E on Page 2). ❑Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser ID: 1-2 Dispenser ID: 3-4 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 5-6 Dispenser ID: 7-8 <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ®Shear Valve(s). ®Shear Valve(s). <br /> ®Dispenser Containment Float(s)and Chain(s). ®Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑Shear Valve(s). <br /> ❑Dispenser Containment Float(s)and Chain(s). ❑Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification -I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br /> correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports,I have also <br /> attached a copy of the report;(check all that apply): ® System set-up ®Alarm history report <br /> Technician Name(print): Nik Zagorov Signature: N?e,rc / <br /> Certification No.: Veeder Root Level 4#A32784 License.No.: 958763 A <br /> Testing Company Name: ECO-CHEK Compliance, Inc. Phone No.:(888) 500-CHEK <br /> Testing Company Address: P.O. Box 1394, Lafayette,CA 94549 Date of Testing/Servicing: 02/27/2018 <br /> Page 1 of 4 <br /> Rev(2/08) <br />
The URL can be used to link to this page
Your browser does not support the video tag.