Laserfiche WebLink
L 4:REGULAR STP SUMP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />OUTPUT RELAY SETUP <br />— — — — — — — — — — — — <br />R I:SUPREME CONTROLL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK <br />IN—TANK ALARMS <br />T 1:HIGH WATER ALARM <br />T 1:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGIRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />MISSING VP INPUT <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:REGULAR CONTROLL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />IN—TANK ALARMS <br />T <br />2:HIGH WATER ALARM <br />LEAK MIN PERIODIC: <br />0% <br />0 <br />PERIODIC TEST TYPE <br />L <br />4:FUEL ALARM <br />STANDARD <br />LEAK MIN ANNUAL <br />0% <br />0 <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST TYPE <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />STANDARD <br />ANNUAL TEST FAIL <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />ALARM DISABLED <br />GROSS TEST FAIL <br />TANK TEST NOTIFY: OFF <br />ALARM DISABLED <br />TNK TST SIPHON BREAKOFF <br />ANN TEST AVERAGING: <br />PER TEST AVERAGING: <br />OFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10-00% <br />TANK TEST NOTIFY: <br />OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY <br />5 MIN <br />PUMP THRESHOLD 10-00% <br />LEAK TEST METHOD <br />— — — — — — <br />— — — — — — <br />TEST ON DATE : TAW I <br />JAN 29, 2009 <br />START TIME : DISABLED <br />T 2:REGULAR <br />TEST,RATE :0.20 GAL/HR <br />2 HOURS <br />PRODUCT CODE <br />2 <br />DURATION <br />THERMAL COEFF :.000700 <br />TANK DIAMETER : 120.00 <br />TST EARLY STOP: DISABLED <br />TANK PROFILE : <br />4 PTS <br />j <br />FULL VOL : <br />90.0 INCH VOL : <br />11849 <br />9894 <br />TEST ON DATE : TANK 2 <br />60.0 INCH VOL : <br />30.0 INCH VOL : <br />6143 <br />2313 <br />JAN 29, 2009 <br />B <br />STA * DISALED <br />TESTRT RATETIME <br />:0.20 GAL/HR <br />DURATION : 2 HOURS <br />FLOAT SIZE: 4.0 <br />IN. <br />TST EARLY STOP:DIsABLED <br />WATER WARNING <br />HIGH WATER LIMIT: <br />1.0 <br />3.0 <br />LEAK 'TEST REPORT FORMAT <br />NORMAL <br />MAX OR LABEL VOL: <br />11849 <br />OVERFILL LIMIT <br />905 <br />10664 <br />HIGH PRODUCT <br />9504 <br />11256 <br />DELIVERY LIMIT <br />5% <br />592 <br />LOW PRODUCT <br />400 <br />LEAK ALARM LIMIT: <br />99 <br />SUDDEN LOSS LIMIT: <br />TANK TILT <br />99 <br />1.05 <br />LIQUID SENSOR SETUP— — — <br />PROBE OFFSET <br />0.00 <br />— — — — — — <br />L J:SUPREME ANNULAR <br />SIPHON MANIFOLDED <br />TANKS <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />T#: NONE <br />4 <br />L 2:SUPREME STP SUMP <br />LEAK MIN PERIODIC: <br />Ir/o <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />0 <br />LEAK MIN ANNUAL <br />0yo <br />L 3:REGULAR ANNULAR <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 4:REGULAR STP SUMP <br />TRI—STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />OUTPUT RELAY SETUP <br />— — — — — — — — — — — — <br />R I:SUPREME CONTROLL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK <br />IN—TANK ALARMS <br />T 1:HIGH WATER ALARM <br />T 1:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGIRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />MISSING VP INPUT <br />ISD SENSOR OUT FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />R 2:REGULAR CONTROLL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />TANK #: 2 <br />IN—TANK ALARMS <br />T <br />2:HIGH WATER ALARM <br />T <br />2:LOW PRODUCT ALARM <br />LIQUID SENSOR ALMS <br />L <br />4:FUEL ALARM <br />L <br />4:SENSOR OUT ALARM <br />L <br />4:SHORT ALARM <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />ISD VP PRES FAIL <br />ISD VP STATUS FAIL <br />ISD HOSE ALARMS <br />ALL:GROSS COLLECT FAIL <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />