My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 3:19:01 PM
Creation date
6/3/2020 9:50:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
I FLOAT SIZE: 4.0 I TEST ON DATE TANK 2 <br /> WATER MINIMUM 0.000 <br /> FLOAT SIZE: 4.0 IN. JAN 2 t9, 2009 . <br /> WATER MINIMUM 0.000 START TIME : DISABLED <br /> WATER WARNING 1 .0 TEST RATE :0.20 GAL/HR <br /> WATER WARNING 1 .0 HIGH WATER LIMIT: 3.0 DURATION 2 HOURS <br /> HIGH WATER LIMIT: 3.0 WATER ALARM FILTER: LOW <br /> WATER ALARM FILTER: LOW TST EARLY STOP:DISABLED <br /> MAX OR LABEL <br /> MAX OR LABEL VOLUME 11849 LEAK TEST REPORT FORMAT <br /> NORMAL <br /> VOLUME : 11849 <br /> HIGH PRODUCT <br /> HIGH PRODUCT % MAK 95.0 <br /> MAX 95.0 (GALLONS) 11257 <br /> (GALLONS) 11257 OVERFILL LIMIT <br /> OVERFILL LIMIT % MAX 90.0 <br /> % MAX 90.0 (GALLONS) 10664 <br /> (GALLONS) 10664 DELIVERY LIMIT <br /> DELIVERY LIMIT % MAX 5.0 <br /> X MAX : 5.0 j (GALLONS) 592 LIQUID SENSOR SETUP <br /> (GALLONS) 592 LOW PRODUCT - - - - - - - - - - - - <br /> LOW PRODUCT VOLUME 400 L 1 :SUPREME ANNULAR <br /> VOLUME 400 LEAK ALARM LIMIT: 99 TRI-STATE (SINGLE FLOAT) <br /> LEAK ALARM LIMIT: 99 TANK TILT <br /> SUDDEN LOSS LIMIT: 99 CATEGORY : ANNULAR SPACE 1 05 <br /> - . <br /> SUDDEN LASS LIMIT: 99 PROBE OFFSET 0.00 <br /> TANK TILT 0.70 <br /> PROBE OFFSET 0.00 I L 2:SUPREME STP SUMP <br /> SIPHON MANIFOLDED TANKS TRI-STATE (SINGLE FLOAT) <br /> SIPHON MANIFOLDED TANKS TO: NONE CATEGORY : STP SUMP <br /> TO: NONE LINE MANIFOLDED TANKS <br /> LINE MANIFOLDED TANKS TO: NONE L 3:REGULAR ANNULAR <br /> TO: NONE TRI-STATE (SINGLE FLOAT) <br /> LEAK MIN PERIODIC: 0% CATEGORY : ANNULAR SPACE <br /> LEAK MIN PERIODIC: 0% 0 <br /> 0 LEAK MIN ANNUAL : 0% <br /> L 4:REGULAR STP SUMP <br /> LEAK MIN ANNUAL : 0% 0 TRI-STATE (SINGLE FLOAT) <br /> 0 CATEGORY : STP SUMP <br /> PERIODIC TEST TYPE <br /> PERIODIC TEST TYPE STANDARD <br /> STANDARD ANNUAL TEST FAIL <br /> ANNUAL TEST FAIL ALARM DISABLED <br /> ALARM DISABLED PERIODIC TEST FAIL <br /> PERIODIC TEST FAIL ALARM DISABLED <br /> ALARM DISABLED GROSS TEST FAIL <br /> GROSS TEST FAIL ALARM DISABLED <br /> ALARM DISABLED OUTPUT RELAY SETUP <br /> ANN TEST AVERAGING: OFF _ _ _ _ _ _ _ - - - - - <br /> ANN TEST AVERAGING: OFF PER TEST AVERAGING: OFF <br /> PER TEST AVERAGING: OFF TANK TEST NOTIFY: OFF R 1 :SUPREME CONTRQLL <br /> TYPE: <br /> TANK TEST NOTIFY: OFF TNK TST SIPHON BREAKOFF STANDARD <br /> TNK TST SIPHON BREAKOFF NORMALLY CLOSED <br /> DELIVERY DELAY 5 MIN ! TANK #: 1 <br /> DELIVERY DELAY 5 MINPUMP THRESHOLD 10.00% <br /> PUMP THRESHOLD 10.00% <br /> IN-TANK ALARMS <br /> 1 T 1 :HIGH WATER ALARM <br /> T 1 :LOW PRODUCT ALARM <br /> LIQUID SENSOR ALMS i <br /> L 2:FUEL ALARM 1 <br /> L 2:SENSOR OUT ALARM ;. <br /> L 2:SHORT ALARM <br /> ISD SITE ALARMS <br /> LEAK TEST METHOD ISD GROSS PRES FAIL <br /> T 2:REGULAR _ _ _ _ _ ISD DEGRD PRES FAIL <br /> PRODUCT CODE 2 TEST ON DATE : TANK 1 ISD VAPOR LEAK FAIL <br /> THERMAL COEFF : .000700 JAN 29. 2009 ISD VP PRES FAIL I <br /> TANK DIAMETER 120.00 ISD VP STATUS FAIL 1 <br /> START TIME : DISABLED <br /> =" <br /> TANK PROFILE 4 FTS TEST RATE :0.20 GAL/HR MISSING VP INPUT <br /> FULL VOL 11849 DURATION : 2 HOURS ISD SENSOR OUT FAIL <br /> 90.0 INCH VOL : 9894 <br /> 60.0 INCH VOL 6143 TST EARLY STOF:DISABLED ISD HOSE ALARMS r <br /> 30.0 INCH VOL 2313 i ALL:GROSS COLLECT FAIL <br /> ALL:DEGRD COLLECT FAIL <br /> ALL:FLOW COLLECT FAIL <br />
The URL can be used to link to this page
Your browser does not support the video tag.