My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HARLAN
>
16500
>
2300 - Underground Storage Tank Program
>
PR0231554
>
COMPLIANCE INFO_2011-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/28/2021 3:19:01 PM
Creation date
6/3/2020 9:50:36 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2018
RECORD_ID
PR0231554
PE
2361
FACILITY_ID
FA0005678
FACILITY_NAME
LATHROP SHELL
STREET_NUMBER
16500
Direction
S
STREET_NAME
HARLAN
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
16500 S HARLAN RD
P_LOCATION
07
P_DISTRICT
003
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231554_16500 S HARLAN_2011-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
427
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd/unitiii.html <br />CONTINUATION FORM <br />Page: 3 of 3 <br />OFFICIAL INSPECTION REPORT <br />Date: 03/10/11 <br />Program: UST <br />Facility Address: Lathrop Shell 16500 South Harlan Road, Lathrop <br />SUMMARY OF VIOLATIONS <br />CLASS I, CLASS 11, or MINOR -Notice to Comply) <br />UST Inspection: Finishing Annual Monitoring System Certification testing <br />24. Annual monitoring system certification testing was last performed on 11/19/09 and was due by <br />11/2010. An monitoring system certification test started 02/07/11 but was incomplete - 87 annular was <br />not able to be removed from interstitial space to be tested since the protective outer sheath covering of <br />the black and red wires was in poor condition and frayed. The wiring was exposed and pulling the <br />annular sensor out would cause tension and possible breakage. The testing of the 87 annular sensor is <br />completed today. Outer sheath wiring was repaired with black electrical tape. Annular passed <br />functionality test. Spill buckets and leak detectors were complete 02/07/11. These tests are required <br />once every 12 months. Be aware that today's follow up inspection will be charged at our current hourly <br />rate. Repeat violation. <br />Submit to SJC EHD within 30 days (03/11/11): <br />1. one copy of the completed "Return to Compliance Certification" form <br />2. a written corrective action statement for the above violation <br />Notes: <br />- Secondary containment next tri -annual testing next due by 06/2011. Provide EHD 48 hours notification <br />of the scheduled test. <br />- Received Spill bucket test results from 02/07/11 today. Comments included written documentation that <br />87 annular sensor tested today and verified sensor length. <br />ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE ($115). <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT END'S CURRENT HOURLY RATE. <br />EHD Insp o : <br />Received By: <br />Title: <br />EHD 23-02-003 Rev 06/01/10 CONTINUATION FORM <br />
The URL can be used to link to this page
Your browser does not support the video tag.