Laserfiche WebLink
46 4 <br />SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />600 East Main Street, Stockton, California 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sigov.oLg/ehd/unitiii.html <br />UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br />Facility name: <br />Inspection date. <br />Lathrop Shell I <br />January 26, 2011 <br />Facility address: <br />UST #1 <br />5 <br />6 <br />16500 South Harlan Road, Lathrop <br />Product <br />87 <br />91 <br />Title: Phone: <br />Facility contact:7 <br />7 <br />Nick Arbabian owner 983-0381 <br />Monitoring panel: <br />Piping system: <br />I Overfill prevention: <br />Violations: <br />Veeder-Root TLS -350 <br />Opressurized Osuction OGravity <br />Ic"Mechanical"EmI <br />0M 1 -RDetect []M2-RPrev 0 W -Both <br />Audible/visual <br />Inspection type: <br />I Designated operator: ICC exp. date: <br />Iffl Routine ❑Monitoring Certification 0 installation 00ther <br />Tony Murch (FranzenHill) 02/25/11 <br />On site Service Technician's name: ICC exp. date: <br />Marjufaptyrees training; <br />technician <br />none -canceled onsite via phone by FranzenHill <br />unavailable. <br />Ito <br />reschedule MC, LD,SB test on 02/07/11. <br /># <br />Code Section VIOLATIONS v <br />R <br />HSC=CA Health & Safety Code; CCR=CA Code of Regulations; V=Violation; RV=Repeat Violation <br />v <br />1 <br />HSC 25284 No permit tooperate <br />Secondary containment: (a) test not performed; (e) test report not submitted within 30 days; (1) test <br />2 <br />CCR 2637 notification not provided to th Environmental Health Department (EHD) at least 48 hours prior to <br />conducting the test t79 00k <br />3 <br />CCR 2711 (b) Current Unified Program Consolidate-dForms not on file with the EHD (Facility and tank form) <br />x <br />4 <br />HSC 25292.2 Current financial responsibility documents not on file with the EHD I --I, (nk <br />x <br />5 <br />CCR 2632(b) Monitoring Program Monitoring & Response Plans) is not current ora roved bi the EHD <br />x <br />6 <br />CCR 2712(i) Monitoring elan, response plan, and/or operatinS permit and all conditions not onsite <br />x I <br />Maintenance & monitoring records not maintained 3 years, cathodic protection records for 6'/2 (MI) <br />years, written performance claims pertaining to release detection systems for 5 years, or records of <br />repairs, linings, and upgrades for the life of the tank. Monitoring records include: (1) date and time of x <br />7 <br />CCR 2712(b) all monitoring or sampling; (2) monitoring equipment calibration and maintenance records; (3) results <br />of any visual observations; (4) results of sample analysis performed a lab or in the field; (5) logs of all <br />readings of gauges or other monitoring equipment, ground water elevations, or other test results; (6) <br />results of inventory readin2s and reconciliations <br />8 <br />CCR 2643(d) Daily monitoring of suction piping (pre -Janus !y 1, 1984) not performed W) <br />9 <br />HSC 25292.1 LIST system is not operated to prevent unauthorized release, including spills and overfills <br />10_ <br />CCR 2632(c)(2) Monitoring system is not present in the interstitial space of a double walled UST (Mi) <br />11 <br />CCR 2630(d) UST monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity(mi) <br />12 <br />HSC 25291(b) UST monitoring system incapable of detecting leak from primary containment into secondary (MI) <br />containment <br />Failed to maintain a continuous monitoring system for underground piping & UDCs that activates (mi) <br />13 <br />CCR 2636(f)(1) an audible and visual alarm or stoes flow of product at the dispenser when it detects a leak <br />14 <br />CCR 2631 (a) Primary containment is not product tight <br />15 <br />HSC 25291(a)(2) Secondary containment for LIST system is not tight <br />16 <br />CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump <br />17 <br />CCR 2636(f)(2) Line leak detector(s) not installed or failed to detect a 3 -gallon per hour leak at 10 psi (MI) <br />Spill container failed to contain a minimum capacity of five gallons, or failed to provide a means (11012) <br />18 <br />CCR 2635(b)(1) to keep the spill container empty <br />19 <br />CCR 2635(b)(2) Overfill prevention system was overridden or failed to meet overfill requirements in this section (W) <br />20 <br />CCR 2636(a) Failed to have secondary containment for pi2ing (includes conventional suction piping) (11012) <br />21 <br />HSC 25291 (e) Water in 20 containment not removed, analyzed & properly disposed of <br />Unauthorized release that: (c) did not escape secondary containment BW cleaned up within eight (mi) <br />22 <br />CCR 2650 hours was not recorded; (e) escaped secondary containment, not cleaned up after eight hours, or a <br />sudden loss of product was not reported to the EHD within 24 hours <br />23a <br />CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br />x <br />I 23b <br />CCR 2715 b Desi Hated o erator did not possess a current ICC LIST System 02erator certification <br />EHD inspect <br />Receive <br />Title: <br />EHD 23-02-002 REV 08113/10 - Page 1 UST INSPECTION REPORT <br />