Laserfiche WebLink
STATE OF CALIFORNIA* WATER RESOURCE'S CONTROL&ARD <br /> FORM W: UNDERGROUND STORAGE TANK PRO AM <br /> TANK TANK PERMIT APPLICATION INFORMATION <br /> COMPLETE A SEPARATE FORM WITH THE FOLLOWING I FORMATION FOR EACH TANK. Fo."'" z <br /> 1 4 <br /> MARK ONLY ❑ 1 NEW PERMIT ❑3 RENEWAL PERMIT 5 CHANGE OF INFORMATION ❑7 PERMANENTLY CLOSED T NK <br /> ONE ITEM ❑2 INTERIM PERMIT F-]4 AMENDED PERMIT ❑6 TEMPORARY TANK CLOSURE ❑8 TANK REMOVED !� <br /> FACILITY/SITE NAME WHERE TANK IS INSTALLED: -,40 S y' (j /� 64ARM TANK-YES NO IV <br /> X23/ <br /> I. TANK DESCRIPTION COMPLETE ALL ITEMS-IF UNKNOWN-SO SPECIFY I-#° <br /> A. OWNERS TANK ID# B. MANUFACTURED BY: 4AI&$,� SNL/V <br /> C.YEAR INSTALLED D. TANK CAPACITY IN GALLONS: (� <br /> II. TANK 92NTENTS IF(A.1),IS MARKED,COMPLETE ITEM C.IF(A.1),IS NOT MARKED,COMPLETE ITEM D. <br /> A. EV1 MOTOR VEHICLE FUEL ❑ 2 PETROLEUM B. C. ❑ 1 UNLEADED ❑ 2 LEADED 3 DIESEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 4 OIL IJ ' PRODUCT ❑ 4 GASAHOL ❑5 JET FUEL ❑ 6 AVIATION GAS <br /> III ❑5 HAZARDOUS ❑ 80 EMPTY ❑ 95 UNKNOWN ❑2 WASTE ❑ 7 METHANOL ❑99 OTHER(DESCRIBE IN ITEM D,BELOW) <br /> D. IF NOT MOTOR VEHICLE FUEL,ENTER NAME OF <br /> i <br /> HAZARDOUS SUBSTANCE STORED&C.A.S.# C.A.S.#: <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOX A,B,C,&D <br /> A.TYPE OF ❑ 1 UBLE WALLED F-13 SINGLE WALLED WITH EXTERIOR LINER ❑95 UNKNOWN <br /> SYSTEM 2 SINGLE WALLED ❑4 SECONDARY CONTAINMENT ❑ 99 OTHER <br /> ❑ 1 STEEL/IRON ❑2 STAINLESS STEEL 3 FIBERGLASS ❑4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> B.TANK <br /> MATERIAL ❑5 CONCRETE ❑6 POLYVINYLCHLORIDE ❑ 7 ALUMINUM F-] 6 100%METHANOL COMPATIBLE FRP <br /> ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ <br /> C.INTERIOR 1 RUBBER LINED F-]2 ALKYD LINING E] 3 EPDXY LINING ❑ 4 PH LIC LINING <br /> LINING ❑5 GLASS LINING ❑6 UNLINED KNOWN <br /> ❑ IS LINING MATERIAL COMPATIBLE WITH 100%METHANOL? ❑YES ❑ NOV91luoITHER <br /> D.CORROSION ❑ 1 POLYETHLENE WRAP ❑2 TAR OR ASPHALT ❑e95VUNKNOWN <br /> L P' ❑4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION E:] 91 NONEL ❑ 99 OTHER <br /> IV. PIPING INFORMATION CIRCLE A IF ABOVE GROUND, U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A.SYSTEM TYPE A(Ij 1 SUCTION A U 2 PRESSURE A U 3 GRAVITY A U 91 NONE A U 95 UNKNOWN A U 99 OTHER <br /> B.CONSTRUCTION A U 1 SINGLE WALLED A U 2 DOUBLE WALLED A U 3 LINED TRENCH A U 91 NONE U 95 UNKNOWN A U 99 OTHER <br /> A U 1 STEEL/IRON A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC) A U 4 FIBERGLASS PIPE A U 91 NONE <br /> C. MATERIAL A U 5 ALUMINUM A 6 CONCRETE A U 7 STEELCLADW/FRP A U 8 100%METHANOL COMPATIBLE FRP <br /> A U 9 GALVANIZED STEEL A U 95 UNKNOWN A U 99 OTHER <br /> V. LEAK DETECTION SYSTEM CIRCLE P FOR PRIMARY,OR S FOR SECONDARY,A PRIMARY LEAK DETECTION SYSTEM MUST BE CIRCLED. <br /> 0S 1 VISUAL CHECK P S 2 INVENTORY RECONCILIATION P S 3 VADOSE WELLS P S 4 ELECTRONIC MONITOR P S 5 GROUND WATER MONITORING WELLS <br /> C <br /> S 6 PRECISION TESTING P S 7 PRESSURE TESTING P S 91 NONE P S 95 UNKNOWN P S 99 OTHER <br /> VI. INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED(MO/YR) 2. ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH <br /> SUBSTANCE REMAINING IN INERT MATERIAL? ❑YE <br /> GALLONS S [:] NO <br /> THIS FORM HAS BEEN COMPLETED UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE,IS TRUE AND CORRECT. <br /> APPLICANT'S NAME(PRINTED&SIGNATURE) DATE <br /> LOCAL AGENCY USE ONLY <br /> COUNTY# JURISDICTION# AGENCY# FACILITY ID# TANK ID# <br /> [M] I I I I El I I Lo-V <br /> CURRENT LOCAL AGENCY FACILITY ID# APPROVED BY NAME PHONE#WITH AREA CODE <br /> PERMIT NUMBER PERMIT APPROVAL DATE PERMIT EXPIRATION DATE Q <br /> CHECK# PERMIT AMOUNT SURCHARGE AMT. FEE CODEECEIPT# BY. <br /> ( 0109?5' <br /> FORM B(6-29-BB) THIS FORM MUST BE ACCOMPANIED BY A FACILITY/SITE APPLICATION, FORM `A,,UNLESS A CURRENT FORMA' HAS BEEN FILED <br /> DATA PROCESSING COPY <br />