My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:54:59 PM
Creation date
6/3/2020 9:50:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Recommended Practices for the Testing and Verification of Spill,Overfill,Leak Detection and Secondary Containment Equipment at UST Facilities <br /> console. If the label is incorrect, contact the 8.3.7 Pass/Fail Criteria. If a sensor triggers an <br /> appropriate person. If no alarm is triggered, alarm when the alarm condition is simulated, and <br /> remove the sensor from the container, check the the sensor is correctly identified on the console,the <br /> connections, allow the liquid to drain from the sensor passes the test. <br /> sensor and immerse it into the liquid again.If the <br /> sensor is replaced,repeat the test procedure. If the sensor does not trigger an alarm when the <br /> alarm condition is simulated, the sensor fails the cr <br /> . Remove the sensor from the test container and test. If the sensor is not correctly identified on the <br /> allow the liquid to drain to clear the alarm. If console, notify the appropriate person to obtain - <br /> product is used as the test liquid, follow the authorization to correct the sensor identification. <br /> manufacturer's instructions for cleaning the <br /> sensor before it is replaced. 8.4 DiscriminatingSensors. The functionality of dis- <br /> inc <br /> .Reinstall the sensor in the proper location and crimating liquid sensors can be determined with the test <br /> method described in Section 8.3.6 and substituting the <br /> position. appropriate product for water. <br /> . Clear the alarm condition on the console. If R <br /> equipped with a printer, print the alarm report <br /> for facility records and indicate that a sensor <br /> functionality test was conducted. <br /> 7.Dispose of product-contaminated water accord- <br /> ing to the guidelines in Section 6.7. <br /> 9 <br /> 3 <br /> O <br /> C <br /> Q <br /> n <br /> a <br /> c <br /> 0 <br /> a <br /> pei.org <br />
The URL can be used to link to this page
Your browser does not support the video tag.