My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
H
>
HOSPITAL
>
500
>
2300 - Underground Storage Tank Program
>
PR0231614
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/19/2021 1:54:59 PM
Creation date
6/3/2020 9:50:52 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231614
PE
2361
FACILITY_ID
FA0000086
FACILITY_NAME
San Joaquin General Hospital
STREET_NUMBER
500
Direction
W
STREET_NAME
HOSPITAL
STREET_TYPE
Rd
City
French Camp
Zip
95231
CURRENT_STATUS
01
SITE_LOCATION
500 W Hospital Rd
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231614_500 W HOSPITAL_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
261
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
t <br /> • UNDERGROUND STORAGE TANK <br /> OVERFILL PREVENTION EQUIPMENT INSPECTIONREPORT FORM (Page 1 of 1) <br /> Type of Action ❑ Installation Inspection ❑Repair Inspection ®36 Month Inspection <br /> I. FACILITY INFORMATION <br /> CERS ID Date of Overfill Prevention Equipment Inspection <br /> 10643278 10/11/2018 <br /> Business Name(Same as Facility Name or DBA-Doing Business As.) <br /> San Joaquin General Hospital <br /> Business Site Address City ZIP Code <br /> 500 W. Hospital Rd French Cam 95231 <br /> II. UNDERGROUND STORAGE TANK SERVICE TECHNICIAN INFORMATION <br /> Name of UST Service Technician Performing the Inspection(Print as shown on the ICC Certification.) Phone# <br /> Eric Mol aard 209 367-4800 Ext. <br /> Contractor/Tank Tester License# ICC Certification# ICC Certification Expiration Date <br /> 774802 8881020 02/25/2019 <br /> Overfill Prevention Equipment Inspection Training and Certifications(List applicable certifications.) <br /> 111. OVERFILL PREVENTION EQUIPMENT INSPECTION INFORMATION <br /> Inspection Method Used: ❑Manufacturer Guidelines(Specify) <br /> ® Industry Code or Engineering Standard(Specify)PEI/RP1200-17 <br /> ❑Engineered Method(Specify) <br /> Attach the inspection procedures and all documentation required to determine the results. #of Attached Pages: <br /> Tank ID: (By tank number,stored product,etc.) RED DIE <br /> What is the tank inside diameter?(Inches) 91 <br /> Is the fill piping secondarily contained? ID Yes ❑No ❑Yes ❑No ❑Yes ❑ No ❑Yes ❑No <br /> Is the vent piping secondarily contained? ❑Yes ®No ❑Yes ❑No ❑Yes ❑No ❑Yes ❑No <br /> OPW <br /> Overfill Prevention Equipment Manufacturer(s) <br /> What is the overfill prevention equipment ®Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow ❑Shuts Off Flow <br /> response when activated? ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow ❑Restricts Flow <br /> (Check all that apply.) <br /> ®AN Alarm ❑AN Alarm ❑A/V Alarm ❑AN Alarm <br /> Are flow restrictors installed on vent piping? ❑Yes ® No ❑Yes ❑No ❑Yes ❑ No ❑Yes ❑No <br /> At what level in the tank is the overfill prevention 81 <br /> set to activate?(Inches from bottom of tank.) <br /> What is the percent capacity of the tank at which 95 <br /> the overfill prevention equipment activates? <br /> Is the overfill prevention in proper operating ®Yes ❑Yes ❑Yes ❑Yes <br /> condition to respond when the substance ❑No ❑ No ❑No ❑No <br /> reaches the appropriate level? (Specify in section V.) (Specify in section V.) pecify'n section V.) (Specify in section V.) <br /> IV. SUMMARY OF INSPECTION RESULTS <br /> Overfill Prevention Inspection Results ®Pass 0 Fail 11 ❑ Pass ❑Fail ❑Pass ❑Fail I ❑ Pass ❑ Fail <br /> V. COMMENTS <br /> All items marked"Fail'must be explained in this section. Any additional comments may also be provided here. <br /> �,z� <br /> Tank level and percentage is based on the 'Shuts Off Flow' method .Y <br /> Tank level with the AN Alarm is set at 76" and the percentage is 90%. Alarm <br /> p <br /> I JkL- <br /> VI. CERTIFICATION BY UST SERVICE TECHNICIAN CONDUCTING THIS INSPECTION <br /> I hereby certify that the overfill prevention equipment was inspected in accordance with California Code of Regulations,title 23,division 3, <br /> chapter 16,section 2637.2 and all the information contained herein is accurate. <br /> UST Service Technician Signatu <br /> If the facility has more comp an this form accommodates,additional copies of this page may be attached. <br /> CERS=California Environmental Retorting System,fD=Identification,UST=Underground storage tank,ICC=International Code CoundiL AN=Audible and visual <br />
The URL can be used to link to this page
Your browser does not support the video tag.