Laserfiche WebLink
i7759 Buttercup Circle, Sonora, CA 95370 <br />Phone: 209-532-7320; Fax: 209-533-2650 <br />California Tank Tester: 90-1068 <br />2005 OCT 21 PM 137 <br />California Contractor 623541 A-Haz r <br />alltech@mlode.com <br />mlode.com c 1 1"J U T <br />EFIV!k0 4 FUDA. T A L <br />,� A I f i 011 r T` I--PrJT <br />MONITOR&6 SVS�' h4 CERTIFICATION <br />A. General Information <br />Facility Name: Olympian Oil Cardlock Date of Testing/Servicing: JAUMP 5 <br />Facility Address: 983 Moffat Blvd., Manteca CA 95336 <br />Facility Contact Person: Nick Bokides Contact Phone No.: (209) 649-3808 LIA: San Joaquin; Ray von Flue <br />Make/Model of Monitoring System: Veeder-Root TLS -350 <br />B. Inventory of Equipment Tested/Certified: <br />Check thea ro ' to boxes to indicate Nneific NMir2eRt ins cted/servieed: <br />Tank ID: Supreme Compartment <br />Tank ID: Regular Compartment <br />M In Tank Gauging Probe. Madel: Mag i <br />® In -Tanis Gauging Probe. Model: Mag 1 <br />M Annular Space or Vault Sensor. Model: Float Switch (Shared) <br />® Annular Space or Vault Sensor. Model: (Shared) <br />M Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />® Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />O Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />1@ Mechanical Line Leak Detector. Model: Red Jacket XL <br />® Mechanical Line Leak Detector. Model: Red Jacket XL <br />O Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector_ Model: <br />M Tank Overfill / High -Level Sensor. Model: Drop Tube <br />® Tank Overfill / High -Level Sensor. Model: Drop Tube <br />Other <br />❑ Other <br />Tank ID: Diesel <br />Tank tD: <br />® In -Tank Gauging Probe. Model: Mag 1 <br />❑ In -Tank Gauging Probe. Model: <br />® Annular Space or Vault Sensor. Model: Float Switch <br />O Annular Space or Vault Sensor. Model: <br />® Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />[] Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: Red Jacket XI. <br />❑ Mechanical Line Leak Detector. Model: <br />O Electronic Line Leak Detector. Model: <br />❑ EIectronic Line Leak Detector. Model: <br />M Tank Overfill / High -Level Sensor. Model: Drop Tube <br />❑ Tank Overfill / High -Level Sensor. Model: <br />D Other <br />❑ Other <br />Dispenser ID: 1&2 MPD M Sump: ®Dry OWater OProduct <br />Dispenser ID. 3&4 MPD M Sump: ®Dry []Water []Product <br />M Dispenser Containment Sensor(s). Model: Liquid sensor <br />M Dispenser Containment Sensor(s). Model: Liquid sensor <br />M Shear Valve(s) (Functional test) <br />® Shear Valve(s) (Functional test) <br />❑ Dis nser Containment Float(s) and Chain(s). <br />❑ Dis user Containment Float(s) and Chain(s). <br />Dispenser ID: 5 M Sump: ®Dry []Water []Product <br />Dispenser ID: 6 M Sump: MDry []Water []Product <br />M Dispenser Containment Sensor(s). Model: Liquid sensor <br />M Dispenser Containment Sensor(s). Model: Liquid sensor <br />M Shear Valve(s) (Functional test) <br />M Shear Valve(s) (Functional test) <br />O Dispenser Containment FI s and Chad s)_ <br />❑ Di!nser Containment Float(s) and Chain(s). <br />Dispenser ID: 7 M Sump: Wry OWater OProduct <br />Dispenser ID: O Sump: []Dry OWater []Product <br />N Dispenser Containment Sensor(s). Model: Liquid sensor <br />❑ Dispenser Containment Sensor(s). Model: x <br />M Shear Valve(s) (Functional test) <br />❑ Shear Valve(s) (Functional test) <br />O Di nser Containment Floats and Chain(s). <br />❑ Dis user Containment Floats and Chain(s). <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the <br />manufacturers' guidelines. Attacked to this Certification is information (eg. manufacturers' checklists) necessary to verify that this <br />information is correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such <br />reports, l have also attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician: / i Mike Dotten, California Contractor License 623541 A -Naz <br />Certif►cation: Veeder-Root:006-05-0789 ; Level 4. <br />ICC UST Technician # 5259412 -UT <br />Page I of 3 06/05 <br />