My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOFFAT
>
983
>
2300 - Underground Storage Tank Program
>
PR0231691
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/6/2023 4:58:56 PM
Creation date
6/3/2020 9:50:59 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231691
PE
2361
FACILITY_ID
FA0003593
FACILITY_NAME
Nella Oil #487
STREET_NUMBER
983
STREET_NAME
MOFFAT
STREET_TYPE
Blvd
City
Manteca
Zip
95336
APN
221-15-06
CURRENT_STATUS
01
SITE_LOCATION
983 Moffat Blvd
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231691_983 MOFFAT_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
410
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
REGEIVEEI�"i <br /> UNDER DISPENSERCONTAINMENT ( _C) TEST114615 <br /> W p®amu" rt -rAfic%r° <br /> Test Method By: o Manufacturer • industry standard o Professional Engr o Other(see below) <br /> Testi Method Uses: 0 'Pressure 0 vacuum • Hydrostatic o Other(see below) <br /> Measuring Equipment Used: "INCON TS-STS (Electronic Sump Test System) <br /> Description Disp#8 Sat <br /> UDC manufacturer Total Containment <br /> UDC material Poly <br /> UDC depth (inches) 38 <br /> Height from UDC bottom to highest 8 <br /> piping penetration <br /> Height from UDC bottom to lowest 12 <br /> electrical penetration <br /> Condition of UDC prior to testing Dry <br /> Portion of UDC tested Entire <br /> Type of shut-down present Sensor <br /> Was sensor removed for testing? Yes <br /> Was sensor properly replaced after testing? Yes <br /> Depth of water level from UDC bottom (in.) 14 <br /> Wait time for water level to stabilize (hr:min) :10 <br /> Test start time 1:44 PM <br /> Initial Probe Reading 3.3122 <br /> Test end time 1:59 PM <br /> Final Probe Reading 3.3121 <br /> Test duration (hr:min) 0:15 <br /> Change in water level (±0.0000 inches) -0.0001 <br /> Pass/Fail threshold (±0.002 inches/;Hr.) 0.0020 <br /> TEST RESULT PASS <br /> Comments: <br /> 0 2015 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.