Laserfiche WebLink
­% 0 <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />FEB 6, 2007 <br />START TIME : DISABLED <br />TEST RATE :0.20 (3AL,,HR <br />DURATION : 2 HOURS <br />TST EARLY STOP :DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />L J:UNLEADED SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L :PREMIUM SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:DIESEL SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 4:ANNULAR SPACE <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 5:DISP 1-2 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 6:DISP 3-4 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L ?:DISP 5-6 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 8:DISP 7-8 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />L 9:DISP 9-10 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />LlO:DISP 10-11 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : DISPENSER PAN <br />OUTPUT RELAY SETUP <br />- -- - - - - - - - - - - <br />R 1:UNLEADED STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />LIO:FOEL ALARM <br />L I:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />LIO:SENSOR OUT ALARM <br />L I:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9:SHORT ALARM <br />LIO:SHORT ALARM <br />L I:WATER ALARM <br />L 5:WATER ALARM <br />L 6:WATER ALARM <br />L 7:WATER ALARM <br />L 8:WATER ALARM <br />L 9:WATER ALARM <br />LIO:WATER ALARM <br />R 2:PREMIUM STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L I:FUEL ALARM <br />L 2:FUEL ALARM <br />L 3:FUEL ALARM <br />1, 4'FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />Llo:FUEL ALARM <br />L 2: SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />L10:SENSOR OUT ALARM <br />L. 2:SHORT ALARM <br />L. 5:SHORT ALARM <br />L. 6:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9:SHORT ALARM <br />LlO:SHORT ALARM <br />L 2:WATER ALARM <br />L 5:WATER ALARM <br />L 6:WATER ALARM <br />L 7:WATER ALARM <br />L 8:WATER ALARM <br />L 9:WATER ALARM <br />1-10:WATER ALARM <br />R 3:DIESEL STP <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 3:FUEL ALARM <br />L 5:FUEL ALARM <br />L 6:FUEL ALARM <br />L 7:FUEL ALARM <br />L 8:FUEL ALARM <br />L 9:FUEL ALARM <br />L10:FUEL ALARM <br />L 3:SENSOR OUT ALARM <br />L 5:SENSOR OUT ALARM <br />L 6:SENSOR OUT ALARM <br />L 7:SENSOR OUT ALARM <br />L 8:SENSOR OUT ALARM <br />L 9:SENSOR OUT ALARM <br />LlO:SENSOR OUT ALARM <br />L 3:SHORT ALARM <br />L 5:SHORT ALARM <br />L 6:SHORT ALARM <br />L 7:SHORT ALARM <br />L 8:SHORT ALARM <br />L 9:SHORT ALARM <br />LIO:SHORT ALARM <br />L 3:WATER ALARM <br />- <br />L 5:WATER ALARM <br />L 6:WATER ALARM <br />L 7:WATER ALARM <br />L 8:WATER ALARM <br />L 9:WATER ALARM <br />Llo:WATER ALARM <br />SOFTWARE REVISION LEVEL <br />VERSION 327.04 <br />SOFTWARE# 346327-100-E <br />CREATED - 07.02.06.10.228 <br />NO SOFTWARE MODULE <br />SYSTEM FEATURES: <br />PERIODIC IN -TANK TESTS <br />ANNUAL IN -TANK TESTS <br />