Laserfiche WebLink
005/14/12008 21:43 FAX 2095332650 ALLTECH PETRO INC Muni Naidu 0]002 <br />Facility Name: Mossdale Arco <br />D. Results of Testing/Servicing <br />Software Version Installed: 18.01 <br />(Page 2) <br />Complete the following <br />checklist: <br />® Yes <br />❑ No* <br />Is the audible alarm operational? <br />Yes <br />❑ No* <br />Is the visual alarm operational? <br />• Yes <br />❑ No* <br />Is the print function operational? ❑ Not installed. <br />• Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed o erational? <br />® Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br />not interfere with their 2roner o eration? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />® N/A <br />operational? <br />M Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ® Sump/Trench Sensors; ® Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? Yes; No. <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />M N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill oin s and o erating properly? If so, at what 2ercent of tank capacity does the alarm trigger? <br />❑ Yes* <br />M No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement 2arts in Section E, below. <br />❑ Yes* <br />M No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />Product; Water. If yes, describe causes in Section E below. <br />Yes <br />No* <br />Was monitorin s tem set-up reviewed to ensure 2r2per settings? Attach set up re orts, if ap2licable <br />® Yes <br />I ❑ No* <br />I Is all monitoring equipment operational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: <br />