Laserfiche WebLink
Petro InO. 9 <br />17759 Buttercup Circle, Sonora, CA 95370 <br />Phone: 209-532-7320; Fax: 209-533-2650 <br />California Tank Tester: 90-1068 <br />California Contractor 623541 A-Haz <br />alltech@mlode.com <br />MONITORING SYSTEM CERTIFICATION Rogow <br />A. General Information <br />Facility Name: Mossdale Arco Date of Testing/Servicing: July 25, 2006 <br />Facility Address: 444 Mossdale Rd., Lathrop CA <br />Facility Contact Person: Nick Bokides Contact Phone No.: (209) 649-3808 LIA: San Joaquin; Ray von Flue <br />Make/Model of Monitoring System: Veeder-Root TLS -350 <br />B. Inventory of Equipment Tested/Certified: <br />Check the appropriate boxes to indicatespecific a ui ment inspected/serviced: <br />Tank ID: Regular Compartment <br />Tank ID: Supreme Compartment <br />® In -Tank Gauging Probe. Model: Mag 1 <br />® In -Tank Gauging Probe. Model: Mag 1 <br />® Annular Space or Vault Sensor. Model: Float Switch (Shared) <br />® Annular Space or Vault Sensor. Model: (Shared) <br />® Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />® Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: Red Jacket XL <br />® Mechanical Line Leak Detector. Model: Vaporless LD -2000 <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />® Tank Overfill / High -Level Sensor. Model: Drop Tube <br />® Tank Overfill / High -Level Sensor. Model: Drop Tube <br />❑ Other <br />❑ Other <br />Tank ID: Diesel Compartment <br />Tank ID: <br />® In -Tank Gauging Probe. Model: Mag 1 <br />❑ In -Tank Gauging Probe. Model: <br />® Annular Space or Vault Sensor. Model: Shared <br />❑ Annular Space or Vault Sensor. Model: <br />® Piping Sump / Trench Sensor(s). Model: Liquid sensor <br />❑ Piping Sump / Trench Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />❑ Fill Sump Sensor(s). Model: <br />® Mechanical Line Leak Detector. Model: Vaporless LD -2000 <br />❑ Mechanical Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />❑ Electronic Line Leak Detector. Model: <br />® Tank Overfill / High -Level Sensor. Model: Drop Tube <br />❑ Tank Overfill / High -Level Sensor. Model: <br />❑ Other <br />❑ Other <br />Dispenser ID: 1&2 ® Sump: ®Dry ❑Water ❑Product <br />Dispenser ID: 3&4 ® Sump: ®Dry ❑Water ❑Product <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Shear Valve(s) (Functional test) <br />® Shear Valve(s) (Functional test) <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dis enser Containment Floats and Chain(s). <br />Dispenser ID: 5&6 ® Sump: ®Dry❑Water ❑Product <br />Dispenser ID: 7&8 ® Sump: ®Dry❑Water ®Product <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Shear Valve(s) (Functional test) <br />® Shear Valve(s) (Functional test) <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dispenser Containment Float(s) and Chain(s). <br />Dispenser ID: 9&10 ® Sump: ®Dry ❑Water ❑Product <br />Dispenser ID: 11&12 ® Sump: ®Dry❑Water ❑Product <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Dispenser Containment Sensor(s). Model: Liquid sensor <br />® Shear Valve(s) (Functional test) <br />® Shear Valve(s) (Functional test) <br />❑ Dispenser Containment Floats and Chain(s). <br />❑ Dis enser Containment Float(s) and Chain(s). <br />C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br />guidelines. Attached to this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is <br />correct and a Plot Plan showing the layout of monitoring equipment. For any equipment capable of generating such reports, I have also <br />attached a copy of the report; (check all that apply): ® System set-up ® Alarm history report <br />Technician: k 1 Mike Dotten, California Contractor's License 623541 A-Haz <br />Certification: Veeder-Root: 006-05-0789; Level 4. <br />ICC UST Technician # 5259412 -UT <br />Page 1 of 3 06/05 <br />