Facility Name: Mossdale (Page 2) <br />D. Results of Testing/Servicing <br />Software Version Installed: Forgot to look. <br />Complete the followins checklist: <br />® Yes <br />❑ No* <br />Is the audible alarm operational? <br />® Yes <br />❑ No* <br />is the visual alarm operational? <br />® Yes <br />❑ No* <br />Is the print function operational? Not installed. <br />® Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed o erational? <br />® Yes <br />❑ No* <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />will not interfere with their pro2er operation? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br />® N/A <br />operational? <br />M Yes <br />❑ No* <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shut -down? (Check all that apply) ® Sump/Trench Sensors; ® Dispenser Containment Sensors. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? ® Yes; ❑ No. <br />❑ Yes <br />❑ No* <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />® N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />fill point(s) and operating ro erl . If so, at what percent of tank capacity does the alarm trigger? <br />❑ Yes* <br />® No <br />Was any monitoring equipment replaced? If yes, identify specific sensors, probes, or other equipment <br />re laced and list the manufacturer name and model for all replacement parts in Section E. below. <br />❑ Yes* <br />® No <br />Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br />❑ Product; ❑ Water. If ye2, describe causes in Section E, below. <br />M Yes <br />[:]No* <br />Was monitoring system set-up reviewed to ensure proper settings? Attach set up reports, if applicable <br />® Yes <br />❑ No* <br />Is all monitoring a ui mentoperational per manufacturer's specifications? <br />* In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. Comments: Each fill -spill bucket was tested in turn with water for thirty minutes and were all found to be tight. At the <br />end of the test the water was emptied into a plastic bucket, labelled as hazardous waste, and left on site. <br />9'd 0992-669 (602) Sal TW "Tiey0 doc:90 60 isI Inr <br />