My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:35:02 AM
Creation date
6/3/2020 9:51:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
All AMI <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sjgov.org/ehd g <br /> Facility Name: Facility Address: Date: <br /> Mossdale Chevron 444 W MOSSDALE RD LATHROP June 19 2015 <br /> Item# Remarks <br /> 306 CCR 2630(d) Monitoring equipment is not installed or maintained to detect a leak at the earliest opportunity. <br /> The diesel sump sensor was located on its side, the sensor in UDC 11/12 was nearly on its onsits side, and sensor in <br /> the 87-octane STP was not located at the lowest point of the sump, all above sensors were not located at the highest <br /> point of their respective sumps and were off the lowest points and not located to detect a leak at the earliest <br /> opportunity. Monitoring equipment shall be maintained to be able to detect a leak at the earliest possible opportunity. <br /> Sensors were relocated to the lowest points of their sumps by the service technician. Ensure that all monitoring <br /> equipment is maintained to detect a leak at the earliest opportunity. This was corrected on site. <br /> This is a Class II violation. <br /> 319 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the diesel STP sump. If water could enter into the secondary containment by precipitation or <br /> infiltration, it must be removed and disposed of properly. The service technician removed approximately 2 cups of <br /> liquid from the diesel sump. Ensure that all sumps and annular spaces are maintained free of liquid. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Onsite to observe monitoring system certification. Routine UST inspection was conducted on May 22, 2015. This is <br /> a chargeable follow-up re-inspection, which is being billed at the EHD's current hourly rate. A checklist was left <br /> onsite at the time of inspection, a full report was mailed to the facility on July 7, 2015. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, 30 days from receipt of your <br /> full inspection report. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> NOTE 1: A permit inspection for the installed new dispensers (permit SR0070498) was also conducted today, SR <br /> inspection report was left onsite. <br /> Received by t Inspector: Phone: Date: <br /> (initial): `j(,il ELENA MANZO, REHS (209) 953-7699 06/19/2015 <br /> J <br /> YVI , Page 5 of 6 <br />