My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:35:02 AM
Creation date
6/3/2020 9:51:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
r } <br /> AOL .9011� <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone: (209) 468-3420 Fax:(209)468-3433 Web:vMW.sjgov.or /c/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Phone: Date: <br /> AUBURN 7700 INC 209 234-1256 May 22, 2016 <br /> Facility Address: CERS ID: <br /> 444 Vvi MOSSDALE RD, LATHROP CA95330 1018055/ <br /> Inspection Contact: Title: Phon g <br /> Paul Sinq Business owner - `��b -���-SO(16 <br /> Inspection Type: Program: <br /> ROUTINE INSPECTION- Ooeratin Permit 2361 - UST FACILITY <br /> Consent For: Consent Given By: <br /> 21 Inspection a Photos � Sam les Paul Sirg, Business oki ner <br /> Service Technician Onsite: Exp.Date: Designated Operator: Exp.Date: <br /> i,QA I NA <br /> Service Technician Manufacturer's Training <br /> CCR=California Code of Regulations NSC=Health and Safety Code CFR=Code of Federal Regulations <br /> V=Violation R=Repeat violation COS=Corrected on site during inspection <br /> File Review <br /> 101 HSC 25284 No permit to operate ■V ❑R ❑COS <br /> 102 HSC 25284(a)(3), No written agreement between tank owner and tank operator to monitor the tank system ❑V ❑R o COS <br /> 103 HSC 25292:2 Current financial responsibility documents not submitted ■V o R o COS <br /> 104 CCR 2711 UST Operating Permit Application for Facility and Tank information not submitted or current o V ❑R o COS <br /> 105 HSC 25286(c) Current BOE number not submitted o V o R o COS <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD ■V ❑R o COS <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed ■V ❑R o COS <br /> 108 CCR 2637(f),2638(e) Failed to notify the EHD 48 hours prior to conducting testing o V o R o COS <br /> r111 <br /> CCR 2637 Failed to test secondary containment o V ❑R ❑COS <br /> CCR2637(e) Failed to submit secondary containment test report within 30 days oV oR o COS <br /> CCR 2638(a) Failed to test monitoring and leak detection equipment annually .V o R o COS <br /> 112 HSC 25284.2 Failed to test spill containers annually ■V o R o COS <br /> 113 CCR 2638(d) Failed to submit monitoring system certification test report within 30 days o V ❑R o COS <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down ■V o R o COS <br /> 115 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days o V o R o COS <br /> 116 CCR 2715 Designated operator,service tech or installer did not possess current ICC certification joV o R o COS <br /> 117 HSC 25292.5 Failed to conduct ELD testing on a system located within 1000'of a public well o R o COS <br /> 118 HSC 25292.5 Failed to repair and retest system due to failed ELD test c2 V o R ❑COS <br /> r12 <br /> CCR 2644.1(a)(5) Failed to submit ELD test results within 60 days ❑V ❑R ❑COS <br /> CCR 2663 Failed to inspect a lined or repaired steel tank within 10 years of lining and every 5 years after o V o R o COS <br /> CCR 2663 Failed to submit tank lining certification within 30days or to conduct proper tests ❑V ❑R ❑COS <br /> HSC 25299 Documents were falsified or misrepresented ❑V ❑R C3 COS <br /> 123 CCR 2661 Permit to repair UST system not obtained o V o R o COS <br /> 124 CCR 2635(d) Failed to submit UST Certification of Installation/Modification ❑V ❑R ❑COS <br /> Received by Inspector: Phone: Date: <br /> (initial): rn ELENA MANZO, REHS (209) 953-7699 05/22/2015 <br /> Page 1 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.