San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209)468-3433 Web:www.sipov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AUBURN 7700 INC 444 W MOSSDALE RD LATHROP 1,May 22 2015 <br /> UST System Observations <br /> 318 CCR 2636(a) Failed to have secondary containment ❑V ❑R ❑COS <br /> 319 HSC 25291(e) Water in secondary containment not removed,analyzed,and properly disposed of(pre-Jul 2003) ❑V ❑R ❑COS <br /> 320 HSC 25290.1(c3), Secondary containment not constructed to prevent water intrusion ❑V ❑R ❑COS <br /> 25290.1(c3) <br /> 321 CCR 2636(c)(1) All releases in secondary piping do not flow to a collection sump C3 V ❑R ❑CDS <br /> [32 <br /> CCR 2636(0(2) Line leak detector not installed ❑V ❑R ❑COS <br /> CCR 2636(1)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi ❑V ❑R ❑COS <br /> CCR 2635(b) No spill bucket installed or failed to provide a means to keep It empty ❑V ❑R ❑COS <br /> CCR 2635(b) Spill container failed to contain a minimum capacity of five gallons ❑V ❑R ❑COS <br /> CCR 2635(b)(2) Overtill prevention system not present,was overridden,or failed to meet overfill requirements ❑V ❑R ❑COS <br /> HSC 25283.5 Unburied below grade UST failed to meet exemption status ❑V ❑R ❑COS <br /> 328 CCR 2717.1(g) Tampered with red tag ❑V ❑R ❑COS <br /> 329 CCR 2717.1(0 Deposited petroleum into a red tagged UST ❑V ❑R ❑COS <br /> 330 HSC 25299(0(2) Tampered with or disabled leak detection devices or alarms ❑V ❑R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored o V ❑R ❑COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V ❑ R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements ❑V ❑R ❑COS <br /> Non-Pressurized Piping <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve ❑V ❑R ❑COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed ❑V ❑R ❑COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> _j <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V ❑ R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑ R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R ❑COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R ❑COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS 11,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 101 HSC 25284 No permit to operate. <br /> Fees for the annual permit to operate the UST system have not beer, paid. No person ira own or operate an UST <br /> unless a perrr,it for its operation has been issued by the local agency to the ovjrler cr operator of the UST system. <br /> Immediately contact the EHD accounting office to make arrangements far payment to obtain a permit to operate a <br /> UST system. <br /> This is a Class I violation. <br /> Received by Inspector: rhon7e: Date: <br /> (initial):V�� ,> � El_EiA?1�ANZ0, RENS { 2053-7659 05/2?_ILO i 5 <br /> age 3 of 6 <br />