My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2010-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
M
>
MOSSDALE
>
444
>
2300 - Underground Storage Tank Program
>
PR0231692
>
COMPLIANCE INFO_2010-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 11:35:02 AM
Creation date
6/3/2020 9:51:23 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2010-2015
RECORD_ID
PR0231692
PE
2361
FACILITY_ID
FA0000212
FACILITY_NAME
Mossdale Chevron
STREET_NUMBER
444
Direction
W
STREET_NAME
MOSSDALE
STREET_TYPE
RD
City
LATHROP
Zip
95330
CURRENT_STATUS
01
SITE_LOCATION
444 W MOSSDALE RD
P_LOCATION
99
P_DISTRICT
005
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231692_444 W MOSSDALE_2010-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
428
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County low <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone.(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> AUBURN 7700 INC 444 W MOSSDALE RD LATHROP May 22 2015 <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 114 CCR 2636(f) Failed to perform 0.1 gph annual line test for pressurized piping without fail safe or shut down. <br /> A cold start of the monitoring panel was conducted on March 12, 2015, however due to the lack of fuel in the lines, no <br /> fail safe or positive shut down was verified at the turbine sumps. An annual line test must be performed for pressurized <br /> piping without fail safe or shut down. Immediately schedule this test and provide 48 hours notification to the EHD. <br /> Please be aware that a follow up inspection will be charged at our current hourly rate. <br /> This is a Class II violation. <br /> 126 HSC 25404(e)(4) Failed to report program data electronically. <br /> The UST Monitoring Site Plan, The UST Certification of Financial Responsibility, UST Response Plan, UST Letter <br /> from Chief Financial Officer, Owner Statement of Designated UST Operator, were not submitted to the the California <br /> Electronic Reporting System (CERS). Beginning January 1, 2014, all businesses are required to submit all new(or <br /> any changes to existing) UST information, including: UST Monitoring Site Plan, UST Certification of Financial <br /> Responsibility, UST Response Plan, UST Owner/Operator Written Agreement(if applicable), UST Letter from Chief <br /> Financial Officer, and Owner Statement of Designated UST Operator Compliance online to the CERS at <br /> http://cers.calepa.ca.gov. Be sure to include any other relevant activities and required fields. <br /> This is a minor violation. <br /> Overall Inspection Comments: <br /> Onsite to conduct a routine UST inspection. The last monitoring system certification and routine UST inspection <br /> were conducted on April 24, 2014 and are past due at this time. This facility is subject to a follow up inspection for <br /> the required monitoring system certification, which will be billed a EHD's current hourly rate. A report copy was <br /> mailed via certified mail to the address on file. <br /> No hazardous waste inspection was conducted today, however several hazardous waste drums were noted inside <br /> the garbage storage area and Mr. Paul Singh stated (via phone) that these drums will be disposed of before final <br /> ownership transfer takes place. According to Mr. Singh, the land ownership transfer occurred in February 2015 anc <br /> business ownership transfer will take place in a few weeks. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by June 22, 2015. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Received by Inspector: Phone: Date: <br /> (initiaq ELENA MANZO, REHS (209) 953-7699 05!22/2015 <br /> Page 6 of 6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.