0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Quik Stop Market#76 Facility 1030 S. Olive St., Stockton Inspection Jul 13, 2012 <br /> Name: p Address: Date: <br /> VIOLATIONS <br /> # C1 C2 M Code Section HSC=CA Health and S Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 violation;M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M7) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS 1,CLASS II,or MINOR-Notice to Comply) <br /> ROUTINE ANNUAL INSPECTION & MONITORING SYSTEM CERTIFICATION <br /> Class II violations: (305, 310) <br /> 305. The Bravo box float and chain in the UDC 1/2 (south) and UDC 3/4 (south) sumps failed to stop the <br /> flow of product at the dispenser when tested. All monitoring equipment shall be maintained to activate <br /> an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. The <br /> service technician adjusted the floats and verified functionality. <br /> REPEAT VIOLATION <br /> 310. Liquid was observed in the 87 and 91 fill sumps. If water could enter into the secondary <br /> containment by precipitation or infiltration, it must be removed and disposed of properly. Immediately <br /> remove this liquid, make a hazardous waste determination per Title 22 hazardous waste regulations, <br /> and manage it accordingly. Ensure that the all sumps are maintained free of liquid. The liquid was <br /> removed by the technician at the time of inspection. <br /> REPEAT VIOLATION <br /> Complete and submit a copy of the Return to Compliance Certification to the EHD by August 13, 2012 <br /> along with a statement documenting the corrective actions that have been or will be taken for each <br /> violation and any supporting paperwork. <br /> Provided: Return to Compliance Certification form <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Received By: Title: <br /> EHD 23-02 v 04/ 12 Page 3 UST INSPECTION REPORT <br />