Laserfiche WebLink
SYWEM SET-UP REPORT -Page 2) <br />T 2:Premium_Unlead <br />- <br />- - <br />PRODUCT CODE <br />B <br />LEAK TEST METHOD <br />OUTPUT RELAY SETUP <br />THERMAL COEFF :.000700 <br />- - - - -- - - - - -- <br />- - - - --- - - - - -- <br />TANK DIAMETER <br />89.75 <br />TEST ON DATE : ALL TANK <br />TANK PROFILE <br />4 PTS <br />FEB 6. 2007 <br />R 1:87 <br />FULL VOL <br />11527 <br />START TIME : DISABLED <br />TYPE: <br />67.3 INCH VOL <br />9379 <br />TEST RATE :0.20 GAL/HR <br />STANDARD <br />44.9 INCH VOL <br />5836 <br />DURATION : 2 HOURS <br />NORMALLY CLOSED <br />22.4 INCH VOL <br />2289 <br />TST EARLY STOP:DISABLED <br />TANK <br />FLOAT SIZE: 4.0 <br />IN. <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />IN -TANK ALARMS <br />WATER WARNING <br />2.0 <br />ALL:HIGH WATER ALARM <br />HIGH WATER LIMIT: <br />3.0 <br />ALL:LOW PRODUCT ALARM <br />MAX OR LABEL VOL: <br />11527 <br />LIQUID SENSOR ALMS <br />OVERFILL LIMIT <br />90% <br />L 1:FUEL ALARM <br />10374 <br />L I:SENSOR OUT ALARM <br />HIGH PRODUCT <br />95% <br />L I:SHORT ALARM <br />10950 <br />DELIVERY LIMIT <br />101% <br />ISLE SITE ALARMS <br />1152 <br />ISL GROSS PRES FAIL <br />ISD DEGRD PRES FAIL <br />LOW PRODUCT <br />637 <br />LIQUID SENSOR SETUP <br />ISD VAPOR LEAK FAIL <br />LEAK ALARM LIMIT: <br />99 - <br />- - - - - - - - - - - - <br />SUDDEN LOSS LIMIT: <br />25 <br />ISD HOSE ALARMS <br />TANK TILT ' <br />3.00 <br />L 1:87 STP SUMP <br />ALL:GROSS COLLECT FAIL <br />PROBE OFFSET <br />0.00 <br />TRI-STATE (SINGLE FLOAT) <br />ALL:DEGRD COLLECT FAIL <br />CATEGORY : STP SUMP <br />ALL:FLOW COLLECT FAIL <br />SIPHON MANIFOLDED <br />TANKS <br />R 2:91 <br />TO: NONE <br />L 2:91 STP SUMP <br />r"PE: <br />LINE MANIFOLDED TANKS <br />TRI-STATE (SINGLE FLOAT) <br />STANDARD <br />TO: NONE <br />CATEGORY : STP SUMP <br />NORMALLY CLOSED <br />TANK 0: 2 <br />LEAK MIN PERIODIC: <br />7B% <br />L 3:87 ANNULAR <br />I <br />8991 <br />DUAL POINT HYDROSTATIC <br />PERIODIC TEST TYPE <br />CATEGORY : ANNULAR SPACE <br />IN -TANK ALARMS <br />STANDARD <br />ALL:HIGH WATER ALARM <br />ALL:LOW PRODUCT ALARM <br />PEkIODIG TEST FAIL <br />ALARM ENABLED <br />L 4:91 ANNULAR <br />LIQUID SENSOR ALMS <br />DUAL POINT HYDROSTATIC <br />L 2:FUEL ALARM <br />GROSS TEST FAIL <br />CATEGORY : ANNULAR SPACE <br />L 2:SENSOR OUT ALARM <br />ALARM ENABLED <br />L 2:SHORT ALARM <br />PER TEST AVERAGING: <br />OFF <br />ISD SITE ALARMS <br />ISD GROSS PRES FAIL <br />TANI'. TEST NOTIFY: <br />OFF <br />ISD DEGRD PRES FAIL <br />ISD VAPOR LEAK FAIL <br />TNK. TST SIPHON BREAKOFF <br />ISD HOSE ALARMS <br />DELIVERY DELAY <br />5 MIN <br />ALL:GROSS COLLECT FAIL <br />PUMP THRESHOLD <br />10.00% <br />ALL:DEGRD COLLECT FAIL <br />ALL:FLOW COLLECT FAIL <br />RECEIVED <br />JUL 2 8 2014 <br />ENVIRONMENTAL HEALTH <br />DEPARTMENT <br />© 2014 Walton Engineering, Inc. <br />