My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
O
>
OLIVE
>
1030
>
2300 - Underground Storage Tank Program
>
PR0231704
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/1/2024 9:07:22 AM
Creation date
6/3/2020 9:51:42 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231704
PE
2361
FACILITY_ID
FA0001060
FACILITY_NAME
QUIK STOP MARKET #2076*
STREET_NUMBER
1030
Direction
S
STREET_NAME
OLIVE
STREET_TYPE
ST
City
STOCKTON
Zip
95215
APN
157-264-22
CURRENT_STATUS
01
SITE_LOCATION
1030 S OLIVE ST
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231704_1030 S OLIVE_2013-2018.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
344
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />UNDER DISPERSER <br />CONTAINMENT <br />I(LIC) TESlw,, 2013 <br />EINIVp <br />i-i"At_ir1 DER r -'is Y"'NT <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other see ielow) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description <br />Disp # 1/2 <br />Dis # 3/4 <br />4.4395 <br />Test end time <br />UDC manufacturer <br />UDC material <br />Bravo <br />Steel <br />Bravo <br />Steel <br />_ <br />Entire <br />Type of shut -down present <br />UDC depth (inches) <br />9" <br />9" <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />PASS <br />PASS <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Port <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />Test start time <br />10:12 AM <br />10:12 AM <br />Initial Probe Reading <br />3.0042 <br />4.4395 <br />Test end time <br />10:28 AM <br />10:28 AM <br />ion of UDC tested <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />Comments: <br />6 <br />6 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />Test start time <br />10:12 AM <br />10:12 AM <br />Initial Probe Reading <br />3.0042 <br />4.4395 <br />Test end time <br />10:28 AM <br />10:28 AM <br />Final Probe Reading <br />3.0027 <br />4.4391 <br />Test duration (hr:min) <br />0:16 <br />0:16 <br />Change in water level (t 0.0000 inches) <br />-0.0015 <br />-0.0004 <br />Pass/Fail threshold (10.002 inches / 14Hr.) <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />02013 Walton Engineering, Inc. <br />
The URL can be used to link to this page