Laserfiche WebLink
AUG-21-2008 02:09 FROM:SCKRASF Ig 209-983-5394 TO:2094683433 PAGE:06 <br /> 'UNDERGROUND STORAGE TANK <br /> RESPONSE PLAN-PAGE 2 <br /> Vt. .LEAK INTERCEPTION AND DETECTION <br /> SYSTEM S E <br /> This information k required til y rot motor vehicle fuel UST systems constructed per the Alternate Construction Requirements of 23 CCR§2533,and only if the Leak <br /> Interception and Detection System (LIDS)docs not meet the volumetric requirements of 23 CCR§2631(d)(1)through(S)(i.e„ when accounting for rainfall and <br /> backfill material,the secondary ehnwinmem volume is less than 100°A of primary tank volume for a single UST;or in the case of multiple U-i rs in shared secondary <br /> containownt,I50®A of the largest primary tank volume or 10"/6 of aggregate primary tank volume,whichever is greater). <br /> ATTACH AN ADDITIONAL PA(„E T'O THIS PLAN CONTAINING THE FOLLOWING INFORMATION; <br /> V- The volume of the LIDS in relation to the volume of the primary container; <br /> H The amount of time the LIDS shall provide containment related to the time between detection of un unauthorized release and eleanup of the leaked substance; <br /> Y 'Ihe depth from the bottom Of the LIDS to the highest anticipated level of groundwater. <br /> The:nature of the unsaturated soils under the LIDS and their ability to absorb contaminants or to allow movement of contaminants; <br /> )i- The methods and scheduling for removal of all hazardous substances which may have been discharged from primary conwinmera and are located in the <br /> unsaturated soils between the rime containment and Aroundwater.including the LIDS same. <br /> VII. REPORTING AND RECORD KEEPING <br /> We will report/nxord any overkill,spill,or unauthorized rulas se from it UST system as indicated in this plan. <br /> Recordable Releasee: Any unauthorized release from primary containment which the UST operator is able to clean up within eight(8)hours after the release was <br /> detected or should reasonably have been detected,and which does not escape from secondary containment,does not increase the hazard of fire or explosion,and does <br /> not cause any deterioration of secondary containment,must be recorded in the facility's monitoring records. Monitoring records must include: <br /> Y The UST operators name and telephone number; <br /> L A list of tha types,quantities,and concentrations of hazardous substances released; <br /> v A description of the action..Laken In control and clean up the release; <br /> D The method and location of disposal of the released hazardous substances.and whether a hatxardous waste manifest was or will be used; <br /> A A description of actions taken to repair the UST and to prevent future relearn; <br /> A description of the method used to reactivate interstitial monitoring after ropluvernent or repair of primary containment, <br /> Reportable Releases: Any overfill,spill,or unuuthorizcd release which escapes from secondary containment(or primary containment if im secondary conutinment <br /> exists),increases the hazard of fire or explosion,nr causes any deterioration of secondary containment,is a reportable rcicuse. Reportable relemes are alsn recordable. <br /> Within 24 hours after a reportable release has been detected,or should have been detected,we will notify the local agency Administering iltc UST program of the <br /> release:,investigate the release,and take immediate measures to stop the release. If necessary,or if required by the local agency,remaining:,crud pm-duct/waste will <br /> Fie removed from the UST to prevent further mleases nr facilitate corrective action. 1f nn emergency exists,we will ratify the State Oftice of Emergency Services. <br /> Within live(5)worsting days of a reporuthle release,we will submit to the local agency a full written report containing all or the following nformalion to the extent <br /> that the information is known at the time of filing the report: <br /> Y The UST owner's or operator's name and telephone number. <br /> L A list of the types,qusnlitiez,and concentrations of hazardous materials released; <br /> >! 'the approximate date of the release; <br /> The date on which the release was discovered; <br /> D The date on which the release was sopped; <br /> )i- A description of aciiuns taken to control and/ax stop the release; <br /> V- A description of corrective and remedial actlnns,including investigations which were undertaken and will be conducted to determine the nature and extent of <br /> soil,ground water or surface water eontamivation due to the release; <br /> 7s The method(s)of cleanup implemented to date,proposed cleanup actions,and a Schedule for implementing the proposed actions; <br /> > The mothod(s)and location(s)ofdisposal of released hazardous materials and any contaminated soils,groundwater,or surface water. <br /> >: Copies of any lwt ardnus w;ww m:mifeste used for off--site transport of hazardous wastes associated with clean-up activity; <br /> p A description of proposed methods for any repair or roplaeament of UST system primary/secondary containment systems; <br /> y A description of additional actions taken to pmvent future rclaasea. <br /> We will fnllow the reporting procedures described above if any of the following conditions occur: <br /> r A recordable unauthoriratd ruleaae can not be cleaned up or is still ander investigation within eight(8)hours of dclectiop; <br /> v Released hazardous substances are discovered at the UST site or in the surrounding area; <br /> * Unusual operating conditions are observed,including erratic behavior of product dispensing equipateat,sudden loss of pm4oci,or the unexplained presence of <br /> water in the Lank,unless system equipment is found to be defective and is immediately repaired or replaced,and no leak has occurred; <br /> Monitoring results from I1ST syxtem rruonitewing equipment/methods indicate that u release may have occurred,unless the monitoring :quipmeot is found ttr be: <br /> defective and is immediately repaired,rec4ibrated,or replaced,and additional monitoring does not confirm the initial results, <br /> Record Retention: Monitoring records and written reports of unauthorized ralowws must be maintained on-site(or off-site at a readily avails ble location,if approved <br /> by the local agency)fbr at least 3 years. Hazardous waste shipping/disposal records(e.g.,manifests)must he maintained for of least 3 yeary fire.,in the date of shipment. <br /> VIII. OWNEWOPERATOR SIGNATURE <br /> CfERTWI .ATION:I ramify tha formation provided herein is true and accurate to the best army knowledge. <br /> OWN ' )p TOftSIGNA RE DATE k� <br /> OPERATORN'A Int) art' OWNER/ PERA RTITWi <br /> / aM' <br /> h e O /rr 'c �� aa- <br /> " ,�S'Atr <br /> (M�--,v U.-0-40 This plan has been reviewed cd;u [R pprpve4 ®Approved With Conditions []Disapproved <br /> Local Agency Signature; /� �Gti�dA, Date: D-7 <br /> SJCEH D-e(06/03)-3/3 06/2#/Qi <br />