My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1999-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
S
>
STIMSON
>
2000
>
2300 - Underground Storage Tank Program
>
PR0231732
>
COMPLIANCE INFO_1999-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 4:09:15 PM
Creation date
6/3/2020 9:51:43 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1999-2010
RECORD_ID
PR0231732
PE
2361
FACILITY_ID
FA0003648
FACILITY_NAME
STKN ARMY AVIATION SUPP FACILITY*
STREET_NUMBER
2000
STREET_NAME
STIMSON
STREET_TYPE
RD
City
STOCKTON
Zip
95206
APN
17726004
CURRENT_STATUS
01
SITE_LOCATION
2000 STIMSON RD
P_LOCATION
99
P_DISTRICT
001
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231732_2000 STIMSON_1999-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
374
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 • <br />A TANK ANNiTUAR TRWINf <br />• Page of <br />Test Method Developed By: Q Tank Manufacturer X Industry Standard- NFPA 30 Q Professional Engineer <br />Q Other (Specify) <br />Test Method Used: Q Pressure X Vacuum Q Hydrostatic <br />X Other (Specify) or acoustical mic UST 2001 <br />Test Equipment Used: UST 2001 or Mc Daniels / 3D test gauges — NIST <br />Equipment Resolution: +/- 0.25% fs <br />Tank # 1 Tank # Tank # Tank # <br />Is Tank Exempt From Testing?' Q Yes XNo <br />Q Yes Q No <br />Q Yes Q No <br />Q Yes Q No <br />Tank Capacity: 15000 <br />Tank Material: Steel <br />Tank Manufacturer: Trusco <br />Product Stored: Jet fuel <br />Wait time between applying <br />pressure/vacuum/water and <br />starting test: <br />Test Start Time: 9am <br />Initial Reading (Rj): 6.6" Hg <br />Test End Time: 10:50 am <br />Final Reading (RF): 6.6" Hg <br />Test Duration: 1 hour 50 min <br />1 hour <br />1 hour <br />Change in Reading (RF -RI): 0.0 <br />Pass/Fail Threshold or Criteria: <br />Test Result: X Pass 0 Fail <br />Pass Fail <br />0 Pass Fail <br />0 Pass Q Fail <br />Was sensor removed for testing? X Yes Q No Q <br />NA <br />Q Yes Q No Q NA <br />Q Yes Q No Q NA <br />Q Yes Q No Q NA <br />Was sensor properly replaced and XYes Q No Q NA <br />verified functional after testing? <br />Q Yes Q No Q NA <br />Q Yes Q No Q NA <br />Q Yes Q No Q NA <br />Comments —(include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />' Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic contairunent <br />testing. f California Code of Regulations, Title 23, Section 2637(a)(6)} <br />
The URL can be used to link to this page
Your browser does not support the video tag.