COMPLIANCE INFO_1996-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_1996-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:32:29 PM
Creation date
6/3/2020 9:52:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2006
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_1996-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
'Monitoring System Certification <br />Fite Address: %Df Testing/Servicing: <br />F. In -Tank Gauging/ SIR Equipment: X—Check this box if tank gauging is used only for inventory control. <br />U Check this box if no tank gauging or SIR equipment is installed. <br />This section must be completed if in -tank gauging equipment is used to perform leak detection nionitoning., <br />Complete the following checklist: <br />U,Yes U N <br />,0 1 Has all input wiring been inspected for proper entry and termination, including testing for ground faults? <br />11 s 11 )Qo* Were all tank gauging probes visually inspected for damage and residue buildup? <br />U -Yes No* Was accuracy of system product level readings tested? <br />• YesNo* Was accuracy of system water level readings tested? <br />• Yesy? C) 0* Were all probes reinstalled properly? <br />U s E03NN Were all items on the equipment manufacturer's maintenance checklist completed? <br />Ilk -the Section ", below, describe how and when these deficiencies were or will be corrected. <br />G. Line Leak Detectors (LLD): El Check this box if LLDs are not installed. <br />C mplete the following checklist: <br />Yes <br />I <br />Q No* <br />Q N/A <br />For equipment start-up or annual equipmeit rtification, was a leak simulated to verify LLD performance? <br />(Check all that apply) Simulated leak rate: V3 g.p.h.; E3 0.1 g.p.h ; 0 0.2 g.p.h. <br />WYes <br />0 No* <br />Were all LLDs confirmed operational and accurate within regulatory requirements? <br />AYes <br />0 No* <br />Was the testing apparatus properly calibrated? <br />11 Yes <br />E3 No* <br />For mechanical LLDs, does the LLD restrict product flow if it detects a leak? <br />Yes <br />13 No* <br />0 N/A <br />For electronic LLDs, does the turbine automatically shut off if the LLD detects a leak? <br />I <br />Yes <br />Q No* <br />(3 N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system is disabled <br />or disconnected? <br />Yes <br />U No* <br />LI N/A <br />For electronic LLDs, does the turbine automatically shut off if any portion of the monitoring system <br />malfunctions or fails a test? <br />Yes <br />Ej No* <br />Q N/A <br />For electronic LLDs, have all accessible wiring connections been visually inspected? <br />es <br />E3 No* <br />Were all items on the equipment manufacturer's maintenance checklist completed? <br />ection H. <br />below. describe [tow anti when flipto dol'iripneipeworp nr will hp enrrpofarl <br />H. Comments: <br />Page 3 of 3 05M I <br />L <br />
The URL can be used to link to this page
Your browser does not support the video tag.