My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1996-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_1996-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:32:29 PM
Creation date
6/3/2020 9:52:02 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1996-2006
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_1996-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
368
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11 <br />Marley Pump Co. <br />California Edition: September 1997 <br />Red Jacket XLP <br />(for Flexible Pipelines) <br />AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br />Certification: Leak rate of 3.0 gph with P0=100% and PFA% <br />Leak Threshold: . 2.0 gph. A leak is declared if the output of the measurement system <br />equals or exceeds this threshold. <br />Applicability: Gasoline, diesel, aviation fuel and solvents. <br />xible pipelines. <br />Specification: System tests pressurized Tests are conducted at peerating pressure. <br />Pipeline Capacity: Maximum of 48.9 gallons. <br />Waiting Time: None between delivery and testing. <br />None between dispensing and testing. <br />Test Period: Response time is less than 3 minutes. <br />System Features: Permanent installation on pipeline. <br />Automatic testing of pipeline. <br />Preset threshold. <br />Single test to determine if pipeline is leaking. <br />Restricted flow to dispenser if leak is deciaed. <br />Y� <br />Calibration: System must be checked annually for capab>'Zity of detecting a line leak of <br />3.0 gph. <br />Marley Pump Co. Evaluator. Ken Wilcox Associates <br />5800 Foxridge Dr. Tei: (816) 443-2494 <br />Mission, KS 66202 <br />Tel: (913) 813-5700 Date of Evaluation: 04/19/93 <br />165 <br />Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of <br />the method or equipment. Equipment should be installed and operated in accordance with all applicable laws and regulations. <br />
The URL can be used to link to this page
Your browser does not support the video tag.