My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:40:58 PM
Creation date
6/3/2020 9:52:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
x �'•p SAN JOAQUIN COUNTY <br /> j ENVIRONMENTAL HEALTH DEPARTMENT <br /> ;. 600 East Main Street, Stockton, CA 95202-3029 <br /> Telephone:(209)468-3420 Fax.(209)468-3433 Web:www.sjgov.ora/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br /> Facility Name: Inspection Date: <br /> Waterloo Food & Fuel Monday, July 19, 2010 <br /> Facility Address: Service Request : <br /> 3030 E. Waterloo, Stockton, CA 95205 SR0060405 <br /> Onsite Service Technician's Name: ICC Service Technician/Installer Exp.Date: Manufacturer Training: <br /> Bryan Mitchell (Donlee Pump) 5293476-UT 5/28/2012 FMS:lnstall (2012);Progrm (2012 <br /> SERVICE SERVICE <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑ mechanical Model: <br /> ❑ ❑ electronic Serial#: ❑ ❑1 hour hydrostatic 13 Incon TS-STS <br /> ❑Caldwell System ❑Other <br /> ❑ line test programmed <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑ ❑mechanical Model: ❑ ❑1 hour hydrostatic ❑Incon TS-STS <br /> ❑electronic Serial#: ❑Caldwell System ❑Other <br /> ❑ line test programmed <br /> Leak detector Spill bucket ❑minimum 5 gallon <br /> ❑ ❑mechanical Model: ❑ ❑1 hour hydrostatic ❑Incon TS-STS <br /> ❑electronic Serial#: ❑Caldwell System ❑Other <br /> ❑line test programmed <br /> 87 Annul sensor Primary piping testing at: <br /> ❑positive shutdown Model: Incon TSP-EIS ❑ p <br /> si <br /> 0 fail safe Serial#:64005 minutes <br /> ❑NA <br /> sensor Secondary containment testing for: <br /> ❑ ❑positive shutdown Model: UDC(s) Piping <br /> ❑fail safe Serial#: Sump(s) UST(s) <br /> ❑NA ❑ <br /> sensor Testing for the above components are next due by: <br /> ❑ ❑positive shutdown Model: <br /> ❑fail safe Serial#: Note: Please be aware that 2°containment components are required to be tested upon <br /> ❑NA installation,6 months after,and every 36 months thereafter. <br /> ❑ Drop tube with mechanical overfill at 95% ❑X Cold start of monitoring panel <br /> ❑ Drop tube with mechanical overfill at 95% ❑ Corrosion protection <br /> ❑ Overfill prevention (see LG letter 150-1) ❑ Other: see below <br /> Observed sensor functionality verification including positive shutdown, sensor out, and fail safe after <br /> replacement of monitoring panel replacement with a new TS-1001 ATG (S/N 59447), and TS-ROM <br /> Relay Output Module. All passed except 87 octane annular sensor. Wayne and Gavim of HMC <br /> replaced the defective sensor with a new Incon annular TSP-EIS annular sensor on an emergency <br /> repair basis. Observed functionality and fail safe verification of the replaced 87 octane annular <br /> sensor. Passed. Submit a permit application of the emergency repair to EHD within 24 working <br /> hours of replacement. Submit Certification of Modification (Form C) to EHD by 8/20/2010. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT MY TIME AT EHD'S CURRENT HOURLY RATE. <br /> EHD Ins ctor 7Received By: Title <br /> EHD 2304 V men UST SERVICE REQUEST INSPECTION REPORT <br /> Rev 06101110 <br />
The URL can be used to link to this page
Your browser does not support the video tag.