My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2007-2012
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3032
>
2300 - Underground Storage Tank Program
>
PR0231758
>
COMPLIANCE INFO_2007-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/21/2023 2:40:58 PM
Creation date
6/3/2020 9:52:06 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007-2012
RECORD_ID
PR0231758
PE
2361
FACILITY_ID
FA0002127
FACILITY_NAME
WESTERN FOOD & FUEL
STREET_NUMBER
3032
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3032 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231758_3032 E WATERLOO_2007-2012.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
340
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br />ENVIRONMENTAL HEALTH DEPARTMENT <br />�e 600 East Main Street, Stockton, CA 95202-3029 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.siaov.org/ehd <br />••'�t'1iI• yt',�l <br />UNDERGROUND STORAGE TANK (UST) PROGRAM SERVICE REQUEST INSPECTION REPORT <br />Fatally Name: <br />Inspection Dale: <br />Waterloo Food & Fuel <br />Friday, July 2, 2010 <br />Fac ft Address: <br />Service Request all: <br />3032 E. Waterloo, Stockton <br />SR0060381 <br />Onsite ServiceTechnicia's Name: <br />ICC Service Technician/InstaRer Exp. Date: <br />ManufachrerTrairft. <br />Robert Barnhart <br />5250450 -UI (4/14/2011) <br />OPW No. P 4809 (1/14/11) <br />SERVICE <br />Leak detector <br />❑ <br />❑ mechanical Model: <br />❑ electronic Serial #: <br />❑ line test programmed <br />® <br />Leak detector <br />❑ <br />❑ mechanical Model: <br />❑ electronic Serial #: <br />❑ <br />❑ line test programmed <br />Leak detector <br />❑ <br />❑ mechanical Model: <br />Cl <br />❑ electronic Serial #: <br />❑ line test programmed <br />sensor <br />❑ <br />❑ positive shutdown Model: <br />❑ <br />❑ fail safe Serial #: <br />❑ NA <br />❑ <br />sensor <br />❑ <br />❑ positive shutdown Model: <br />❑ <br />❑ fail safe Serial #: <br />❑ NA <br />sensor <br />sitive shutdown Model: <br />❑po�7 <br />13 fail safe Serial #: <br />❑ NA <br />❑ <br />Drop tube with mechanical overfill at 95% <br />❑ <br />Drop tube with mechanical overfill at 95% <br />0-1 <br />Overfill prevention (see LIS letter 150-1) <br />SERVICE <br />87 Spill bucket O minimum 5 gallon <br />IF _ihour hydrostatic D Incon TS -STS <br />© Caldwell System D Other <br />DSL Spill bucket D minimum 5 gallon <br />® <br />WTour hydrostatic D lncon TS -STS <br />O cd"all system O Other <br />30 bucket O minimum 5 gallon <br />❑ <br />T 1 hour hydrostatic O Mcon TS -STS <br />O Caldwell System O Other <br />P* wy Piping W" at: <br />Cl <br />Psi <br />mirpAse <br />Secondary containment testing for: <br />UDC(s) Piping <br />Sump(s) UST(s) <br />❑ <br />T*Wq for the above components are next due by: <br />Nott: Maps be aware that 2- aMairrnent components are required to be tested upon <br />instsk*m, 6 molts ~, and every 36 months mereatter. <br />❑ <br />Cold start of monitoring panel <br />❑ <br />Corrosion protection <br />❑ <br />Other: see below <br />-Observed 1 -hour hydrostatic test of the repaired 87 grade Spill Bucket, diesel Spill Bucket. Passed. <br />May resume deposition of fuel into these two tanks. <br />-The 91 grade Spill Bucket was not replaced during this inspection and no concrete was broken. <br />Deposition of fuel into the 91 grade Spill Bucket is not allowed until the Spill Bucket is replaced and <br />passed the 1 -hour hydrostatic test. <br />- Note: EHD observed the 87 grade Leak Detector replacement and functionality test on 6/30/2010. <br />See separate SR report. <br />THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br />Retxived 11y, Title: <br />EIO 2}0+CD UST SERVICE REQUEST INSPECTION REPORT <br />!!w OMO1N0 <br />
The URL can be used to link to this page
Your browser does not support the video tag.