Laserfiche WebLink
0 0 y0 <br /> STATE OF CALIFORNIA '"y <br /> c' <br /> STATE WATER RESOURCES CONTROL BOARD ; <br /> UNDERGROUND STORAGE TANK PERMIT APPLICATION-FORM B y <br /> . 3.. . 1 <br /> COMPLETE A SEPARATE FORM FOR EACH TANK SYSTEM. "~ <br /> MARK ONLY ❑ 1 NEW PERMIT ❑ 3 RENEWAL PERMIT ❑ 5 CHANGE OF INFORMATION ❑ 7 PERMANENTLY CLOSED ONSITE <br /> ONE REM ❑ 2 INTERIM PERMIT 4 AMENDED PERMIT ❑ 8 TEMPORARY TANK CLOSURE ❑ 8 TANK REMOVED_X:7 h Ile /S J <br /> DBA OR FACILITY NAME WHERE TANK IS INSTALLED: % <br /> 1. TANK DESCRIPTION COMPLETE ALL ITEMS- SPECIFY IF UNKNOWN <br /> A. OWNER'S TANK I.D.A 0 (_ — 1;)l — B. MANUFACTURED BY: v C 0 <br /> C. DATE INSTALLED(MO/DAY/YEAR) 1� ® C-r D. TANK CAPACITY IN GALLONS: too <br /> ILTANKCONTENTS IFA•11SMARKED,COMPLETE ITEM C. Ih15 tG� Z j 0,b®CJ z5fIi-1- <br /> A. 1 MOTOR VEHICLE FUEL F74 OIL B. C. F77 la REGULAR 3 DIESEL UNLEADED ❑ 6 AVIATION GAS <br /> F7 2 PETROLEUM ED 80 EMPTY 1 PRODUCT 1b PREMIUM 4 GASAHOL ❑ 7 METHANOL <br /> UNLEADED ❑ 5 JET FUEL <br /> ❑ 3 CHEMICAL PRODUCT ❑ 95 UNKNOWN ❑ 2 WASTE ❑ 2 LEADED ❑ 99 OTHER (DESCRIBE IN ITEM D. BELOW) <br /> D. IF(A.1)IS NOT MARKED, ENTER NAME OF SUBSTANCE STORED 41W C.A.S.• <br /> III. TANK CONSTRUCTION MARK ONE ITEM ONLY IN BOXES A,B.AND C,AND ALL THAT APPLIES IN BOX D AND E <br /> A. TYPE OF 1 DOUBLE WALL ❑ 3 SINGLE WALL WITH EXTERIOR LINER ❑ 95 UNKNOWN <br /> SYSTEM ❑ 2 SINGLE WALL ❑ 4 SECONDARY CONTAINMENT (VAULTED TANK) ❑ 99 OTHER <br /> ❑ <br /> B. TANK i BARE STEEL F72 STAINLESS STEEL ❑ 3 FIBERGLASS 4 STEEL CLAD W/FIBERGLASS REINFORCED PLASTIC <br /> MATERIAL ❑ 5 CONCRETE ❑ 6 POLYVINYL CHLORIDE ❑ 7 ALUMINUM ❑ 8 100% METHANOL COMPATIBLE W/FRP <br /> (PrimaryTank) ❑ 9 BRONZE ❑ 10 GALVANIZED STEEL ❑ 95 UNKNOWN ❑ 99 OTHER <br /> ❑ 1 RUBBER LINED ALKYD LINING ❑ 3 EPDXY LINING ❑ 4 PHENOLIC LINING <br /> C.INTERIOR ❑ 5 GLASS LINING 6 UNLINED ❑ 95 UNKNOWN ❑ 99 OTHER <br /> LINING <br /> IS LINING MATERIAL COMPATIBLE WITH 100% METHANOL? YES_'Z__NO_ <br /> D.CORROSION ❑ 1 POLYETHYLENE WRAP ❑ 2 COATING ❑ 3 VINYL WRAP 4 FIBERGLASS REINFORCED PLASTIC <br /> PROTECTION ❑ 5 CATHODIC PROTECTION ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> E.SPILL AND OVERFILL SPILL CONTAINMENT INSTALLED(YEAR)... q_cr- OVERFILL PREVENTION EQUIPMENT INSTALLED(YEAR) <br /> IV.PIPING INFORMATION CIRCLE A IFABOVEGROUNDOR U IF UNDERGROUND,BOTH IF APPLICABLE <br /> A. SYSTEM TYPE A U 1 SUCTION An 2 PRESSURE A U 3 GRAVITY A U 99 OTHER <br /> B. CONSTRUCTION A U 1 SINGLE WALL A(D 2 DOUBLE WALL A U 3 LINED TRENCH A U 95 UNKNOWN A U 99 OTHER <br /> C. MATERIAL AND A U 1 BARE STEEL A U 2 STAINLESS STEEL A U 3 POLYVINYL CHLORIDE(PVC)Ao 4 FIBERGLASS PIPE <br /> CORROSION A U 5 ALUMINUM A U 6 CONCRETE A U 7 STEEL W/COATING A U 8 100% METHANOL COMPATIBLE W/FRP <br /> PROTECTION A U 9 GALVANIZED STEEL A U 10 CATHODIC PROTECTION A U 95 UNKNOWN A U 99 OTHER <br /> D. LEAK DETECTION V 1 AUTOMATIC LINE LEAK DETECTOR ❑ 2 LINE TIGHTNESS TESTING 3 MONRORING ❑99 OTHER <br /> V.TANK LEAK DETECTION <br /> ❑ 1 VISUAL CHECK ❑ 2 INVENTORY RECONCILIATION ❑ 3 VADOZE MONITORING 4 AUTOMATIC TANK GAUGING ❑ 5 GROUNDWATER MONITORING <br /> ❑ 6 TANK TESTING V7 INTERSTITIAL MONITORING ❑ 91 NONE ❑ 95 UNKNOWN ❑ 99 OTHER <br /> VI.TANK CLOSURE INFORMATION <br /> 1.ESTIMATED DATE LAST USED(MO/DAY/YR 2.ESTIMATED QUANTITY OF 3.WAS TANK FILLED WITH YES ❑ NO❑ <br /> SUBSTANCE REMAINING RIAL <br /> GALLONS INERT MATE ? <br /> THIS FORM HAS BEEN CO ETA UNDER PENALTY OF PERJURY,AND TO THE BEST OF MY KNOWLEDGE, IS TRUE AND CORRECT <br /> APPLICANTS NAME e DAT <br /> JO (PRINTED a SIGNAT ) ! d c- OCT_? <br /> LOCAL AGENCY USE ONLU <br /> Y THE TATE I.D.NI IS COMPOSED OF THE FOUR NUMBERS BELOW ��� <br /> COUNTY# JURISDICTION# FACILITY# TANK#00 <br /> STATE I.D.# DUN] <br /> PERMIT NUMBER ��/l�b PERMIT APPROVEDBY/DATE PERMIT EXPIRATION DATE 1017196,7 <br /> 96 <br /> THIS FORM MUST BE ACCOMP IED BY A PERMIT APPLICATION-FORMA,UNLESS A CURRENT FORMA HAS BEEN FI E . <br /> FILE THIS FORM WITH OCAL AGENCY IMPLEMENTING THE UNDERGROUNDS* <br /> TANK REGULATIONS <br /> FORM (12-91) 3�—/� — <br />