My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2002-2010
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
5611
>
2300 - Underground Storage Tank Program
>
PR0231764
>
COMPLIANCE INFO_2002-2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2023 3:20:02 PM
Creation date
6/3/2020 9:52:16 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2002-2010
RECORD_ID
PR0231764
PE
2361
FACILITY_ID
FA0002160
FACILITY_NAME
BlackHawk Petroleum Inc.
STREET_NUMBER
5611
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
RD
City
STOCKTON
Zip
95215
APN
08710052
CURRENT_STATUS
01
SITE_LOCATION
5611 E WATERLOO RD
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231764_5611 E WATERLOO_2002-2010.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
498
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
12/06/2010 14:35 209-465-4988 HMC HENDERSON MAINT PAGE 02/03 <br /> SWRCB,January 2002 page—of <br /> 7. UNDER-DISPENSER C <br /> Test Method Developed By. 0 UDC Manufacturer VIndustry Standard 12 Professional bagmeer <br /> 0 Other AMC& <br /> Test Method Used:, 0 Pressure 0 vacuum Hydrostatic <br /> 0 other(,Specify) <br /> Test EquipmentUsed,TS STS Equipment Resolution:0.0001" <br /> 2 UDC#3-4 UDC# UDC# <br /> UDC aturw- BRAVO BRAVO <br /> UDC Material: STEEL STEEL <br /> ep <br /> UDC D an th: 10 10 <br /> M <br /> UDC <br /> Tjr&TDM' <br /> UDC <br /> from UDC Bottom to Top 0 0 <br /> of F[Mgg Pi is Penetration: <br /> Height from UDC Bottom to 0 0 <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to GOOD GOOD <br /> Portion of UDC Tested <br /> Does turbine shut down when <br /> UDC sensor detects liquid(both D yes oNo c-NA 0 Yes 0 No DNA OYes ONO DNA OYes DNo DNA <br /> product and water)?' <br /> Turbine shutdownTRM!S�tne <br /> is system programmed for fail- 0 Yes ONo DNA 0 Yes :3 No DNA []Yes EINo DNA QYes 0,114o DNA <br /> cap-qhiMqwn?* <br /> Was fail-safe verified to be 0 Yes 0 No DNA 0 Yes OWo DNA OYes OM ONA OYes 014o DNA <br /> Wait time between applying <br /> pressmWvacmuntwaterand <br /> startis test <br /> Test Start Thna. 1005 1057 <br /> Initial Reading LQ <br /> 2.8985 0.1225 <br /> Test End Time: 1020 1112 <br /> Final Rea-j'jii' 2.8982 0.1219 <br /> Test Duration: 15 MW 15 WM <br /> Change in Rgft Rt R,): 0.0003 0.0006 <br /> Pass/Pail Threshold or Criteria: 0.002 0.002 <br /> Test Result &_Pass. mLgil JKPa's OFa 0 Pass 0F2fl 0 Pass 0 FaG <br /> Was sensor removed for testi a? 0 Yes 0 No 0 NA OYes ONo DNA OYes ONO DNA OYes ON6 DNA <br /> Was sensor properly replaced and <br /> 0 Yes 0 No 13 NA I OYes ONo 13NA UYes ONo DNA 0 Yes 0 No 0 NA <br /> verified functional after teone, I i <br /> Comm airs made prior tot�iandrecammendedfoLlow-up !ttes�) .. <br /> If the entire depth of the UDC is not tested,specify how much was tested. If the answer to_M of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire UDC must be tested. (See SWRCBLG-160) <br />
The URL can be used to link to this page
Your browser does not support the video tag.