Laserfiche WebLink
E <br />T 4:DIESEL <br />PRODUCT CODE 4 <br />THERMAL COEFF :.000450 <br />TANK DIAMETER 96.00 <br />TANK PROFILE 1 PT <br />FULL VOL 12000 <br />FLOAT SIZE: 3.0 IN. <br />WATEF WARNING <br />1.0 <br />HIGH WATER LIMIT: <br />2.0 <br />MAX OR LABEL VOL: <br />12000 <br />OVERFILL LIMIT <br />90% <br />10800 <br />HIGH PRODUCT <br />95% <br />11400 <br />DELIVERY LIMIT <br />10% <br />1200 <br />LOW PRODUCT <br />1000 <br />LEAK ALARM LIMIT: <br />99 <br />SUDD17N LOSS LIMIT: <br />99 <br />TANK TILT <br />0.00 <br />PROBE OFFSET <br />0.00 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />OCT 10, 2003 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />LIQUID SENSOR SETUP <br />- - -- - - - - - - - - - <br />L I:RED DIESEL ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 2:RED DIESEL STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:E37 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 4:07 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 5:DIESEL ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 6:DIESEL STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />OUTPUT RELAY SETUP <br />- - -- - - - - - - - - - <br />R 1:87 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 4:FUEL ALARM <br />L 4:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />R 2:F?ED DIESEL <br />TYPE: <br />ST(iNDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />R 3:DIESEL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />IN -TANK ALARMS <br />T 4:11AX PRODUCT ALARM <br />T 2:PER TST NEEDED ALM <br />LIQUID SENSOR ALMS <br />L 6:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />SMARTSENSOR SETUP <br />s 1:11RESSURE <br />CATEGORY VAPOR PRESSURE <br />s 2:VAPOR VALVE <br />CATEGORY VAPOR VALVE <br />s 8: ATM P <br />CATEGORY ATM P SENSOR <br />PMC ',:)ETUP <br />PMC VERSION: 01.02 <br />VAPOF-'.' PROCESSOR TYPE <br />VEEDER-ROOT POLISHER <br />ANALYSIS TIMES <br />TIME: 10:00 AM <br />DELAY MINUTES: 1 <br />