COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
UNDER DISPERSER CONTAINMENT DC) TESTING <br />Test Method By: o Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description Disn # 1 Dirn it 2 nicn it 3/d nicn fi 5 <br />UDC manufacturer <br />UDC material <br />UDC depth (inches) <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />Bravo <br />Steel <br />9 <br />Height from UDC bottom to highest <br />piping penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />Height from UDC bottom to lowest <br />electrical penetration <br />Bottom <br />Bottom <br />Bottom <br />Bottom <br />Condition of UDC prior to testing <br />Dry <br />Dry <br />Dry <br />Dry <br />Portion of UDC tested <br />Entire <br />Entire <br />Entire <br />Entire <br />Type of shut -down present <br />Float <br />Float <br />Float <br />Float <br />Was sensor removed for testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Was sensor properly replaced after testing? <br />N/A <br />N/A <br />N/A <br />N/A <br />Depth of water level from UDC bottom (in.) <br />6" <br />6" <br />6" <br />6" <br />Wait time for water level to stabilize (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Test start time <br />10:39 AM <br />10:39 AM <br />11:36 AM <br />11:36 AM <br />Initial Probe Reading <br />3.4310 <br />4.4084 <br />2.7218 <br />2.9789 <br />Test end time <br />10:54 AM <br />10:54 AM <br />11:51 AM <br />11:51 AM <br />Final Probe Reading <br />3.4309 <br />4.4077 <br />2.7217 <br />2.9787 <br />Test duration (hrmin) <br />0:15 <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0001 <br />-0.0007 <br />-0.0001 <br />-0.0002 <br />Pass/Fail threshold (±0.002 inches /'4 Hr.) <br />TEST RESULT <br />0.0020 <br />PASS <br />0.0020 <br />PASS <br />0.0020 <br />PASS <br />0.0020 <br />PASS <br />Comments: <br />© 2014 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.