© 2014 Walton Engineering, Inc. <br />SYff EM SET-UP REPORT <br />(Page <br />2) <br />T 4:DIESEL <br />LEAK TEST METHOD <br />OUTPUT RELAY SETUP <br />PMC SETUP <br />PRODUCT CODE 4 <br />_ <br />THERMAL :.000450 <br />TEST ON DATE : ALL TANK <br />TANK DIAMETER <br />ETER 96.00 <br />OCT 10, 2003 <br />k 1.87 <br />PMC VERSION: 01.04 <br />TANK PROFILE 1 PT <br />START TIME DISABLED <br />TYPE: <br />FULL VOL 12000 <br />TEST RATE :0.20 GAL/ HR <br />STANDARD <br />VAPOR PROCESSOR TYPE <br />DURATION : 2 HOURS <br />NORMALLY CLOSED <br />VEEDER-ROOT POLISHER <br />FLOAT SIZE: 3.0 IN. <br />TST EARLY STOP:DISABLED <br />WATER MINIMUM 0.000 <br />LIQUID SENSOR ALMS <br />ANALYSIS TIMES <br />TIME: 10:00 AM <br />LEAK TEST REPORT FORMAT <br />L 4:FUEL ALARM <br />DELAY MINUTES: 1 <br />WATER WARNING 1.0 <br />NORMAL <br />L 4:SENSOR OUT ALARM <br />HIGH WATER LIMIT: 2.0 <br />L 4:SHORT ALARM <br />WATER ALARM FILTER: LOW <br />LIQUID SENSOR SETUP <br />R 2:RED DIESEL <br />- - - - - - - - - - - - <br />TYPE: <br />MAX OR LABEL <br />STANDARD <br />VOLUME 12000 <br />L 1:RED DIESEL ANNULAR <br />NORMALLY CLOSED <br />HIGH PRODUCT <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORYANNULAR SPACE <br />% MAX 95.0 <br />(GALLONS) 11400 <br />LIQUID SENSOR ALMS <br />L 2:FUEL ALARM <br />SOFTWARE.REVISION LEVEL <br />L 2:SENSOR OUT ALARM <br />VERSION 333.04 <br />OVERFILL LIMIT <br />�; <br />L RED DIESEL STP SUMP <br />L 2:SHORT ALARM <br />SOFTWARE# 346333-100-E <br />CREATED - 13.06.07.08.25 <br />% MAX 90.0 <br />TRI-STATE (SINGLE FLOAT) <br />(GALLONS) 10800 <br />CATEGORY : STP SUMP <br />R 3:DIESEL <br />NO SOFTWARE MODULE <br />DELIVERY LIMIT <br />TYPE: <br />STANDARD <br />SYSTEM FEATURES: <br />% MAX 10.0 <br />L 3:67 ANNULAR <br />NORMALLY CLOSED <br />PERIODIC IN -TANK TESTS <br />ANNUAL IN -TANK TESTS <br />(GALLONS) 1200 <br />TRI-STATE (SINGLE FLOAT) <br />LOW PRODUCT <br />CATEGORY : ANNULAR SPACE <br />LIQUID SENSOR ALMS <br />VOLUME 1000 <br />L 6:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />LEAK ALARM LIMIT: 99 <br />L 4:87 STP SUMP <br />L 6:SHORT ALARM <br />SUDDEN LOSS LIMIT: 99 <br />TRI-STATE (SINGLE FLOAT) <br />TANK TILT 0.00 <br />CATEGORY : STP SUMP <br />SMARTSENSOR SETUP <br />PROBE OFFSET 0.00 <br />- - - - - - - - - - - - <br />L 5:DIESEL ANNULAR <br />5 I:PRESSURE <br />SIPHON MANIFOLDED TANKS <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY VAPOR PRESSURE <br />TO: NONE <br />CATEGORY : ANNULAR SPACE <br />LINE MANIFOLDED TANKS <br />s 2:VAPOR VALVE <br />TO: NONE <br />CATEGORY VAPOR VALVE <br />L 6:DIESEL STP SUMP <br />5 8:ATM P <br />LEAK MIN PERIODIC: 0% <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY ATM P SENSOR <br />0 <br />CATEGORY STP SUMP <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE <br />STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10.00°%, <br />© 2014 Walton Engineering, Inc. <br />