Laserfiche WebLink
MONITSRING SYSTEM CERTI ATI -, <br />CERTIFICATION /TEST DATE: February 18, 2014 FEB 2 8 2014 <br />A1. FACILITY A2. OWNER <br />Name Olympian # 427 Name Flyers Energy LLC. HEALTH DEPARTMENT <br />Address 3300 Waterloo Road, Stockton, CA 95205 Address 2360 Lindbergh Street, Auburn, CA 95602 <br />Phone # 530-885-0401 Phone # 530-885-0401 <br />Contact Amanda Appelt contact Amanda Appelt <br />D. RESULTS OF TESTING / SERVICING <br />Make / Model of Monitoring System: Veeder-Root TLS -350 SN# <br />Software Version Installed: 329.01 <br />Complete the following checklist: <br />■ Yes <br />❑ No* <br />is the audible alarm operational? <br />■ Yes <br />❑ No* <br />Is the visual alarm operational? <br />■ Yes <br />❑ No* <br />Were all sensors visually inspected, functionally tested, and confirmed operational? <br />Were all sensors installed at lowest point of secondary containment and positioned so that other equipment <br />■ Yes <br />❑ No* <br />will not interfere with their proper operation? <br />❑ Yes <br />❑ No* <br />If alarms are relayed to a remote monitoring station, Is all communications equipment (e.g. modems) <br />■ N/A <br />❑ No* <br />operational? <br />For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br />■ Yes <br />❑ N/A <br />monitoring system detects a leak, fails to operate, or is electrically disconnected? If yes: which sensors initiate <br />positive shutdown? (check all that apply) ■ Sump/Trench sensors; ❑ Dispenser Containment Sensors. <br />■ Yes <br />❑ No* <br />❑ No. <br />Did you confirm positive shut -down due to leaks and sensor failure/disconnection? <br />For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br />❑ Yes <br />■ N/A <br />mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br />■ No <br />fill point(s) and operating properly? If so, at what percent of tank capacity does the alarm trigger? _ % <br />❑ Yes * <br />Was any monitoring equipment replaced? If yes, Identify specific sensors, probes, or other equipment replaced <br />and list the manufacturer name and model for all replacement parts in Section E, below. <br />❑ Yes * <br />■ No <br />Was any liquid found Inside any secondary containment systems designed as dry systems? <br />(Check all that apply) ❑ Product; ❑ Water. If yes, describe causes in Section E, below. <br />■ Yes <br />❑ No* <br />Was monitoring system set-up reviewed to insure proper settings? Attach set-up reports, if applicable. <br />■ Yes <br />❑ No* <br />Is all monitoring equipment operational per manufacturer's specifications? <br />In Section E below, describe how and when these deficiencies were or will be corrected. <br />E. COMMENTS <br />Unable to test the Red Diesel STP sump sensor for positive shutdown, sensor out, or fail-safe. <br />Page 2 of 3 <br />