Laserfiche WebLink
0 2013 Walton Engineering, Inc. <br />A a <br />SY EM SET-UP REPOR <br />(Page2) <br />- - - <br />QFC 2 0 2033 <br />T 4:DIESEL <br />PRODUCT CODE 4 <br />LIQUID SENSOR SETUP <br />SMARTSENSOR SETUP <br />ENVIRONMENTS <br />THERMAL COEFF :.000450 <br />- - - - -- - - - - -- <br />---- -- ---- <br />TANK DIAMETER 96.00 <br />HEALTH DFaPAR -Al ENT <br />TANK PROFILE 1 PT <br />L 1:RED DIESEL ANNULAR <br />5 1:PRESSURE <br />FULL VOL 12000 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY VAPOR PRESSURE <br />CATEGORY : ANNULAR SPACE <br />5 2:VAPOR VALVE <br />FLOAT SIZE: 3.0 IN. <br />CATEGORY VAPOR VALVE <br />WATER WARNING 1.0 <br />L 2:RED DIESEL STP SUMP <br />5 8:ATM P <br />HIGH WATER LIMIT: 2.0 <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY ATM P SENSOR <br />CATEGORY : STP SUMP <br />MAX OR LABEL VOL: 12000 <br />OVERFILL LIMIT 90% <br />10800 <br />L 3:87 ANNULAR <br />HIGH PRODUCT 95% <br />TRI-STATE (SINGLE FLOAT) <br />11400 <br />CATEGORY : ANNULAR SPACE <br />DELIVERY LIMIT 10% <br />1200 <br />LOW PRODUCT 1000 <br />L 4:87 STP SUMP <br />LEAK ALARM LIMIT: 99 <br />TRI-STATE (SINGLE FLOAT) <br />SUDDEN LOSS LIMIT: 99 <br />CATEGORY : STP SUMP <br />TANK TILT 0.00 <br />PMC SETUP <br />PROBE OFFSET 0.00 <br />L 5:DIESEL ANNULAR <br />PMC VERSION: 01.02 <br />TRI-STATE (SINGLE FLOAT) <br />SIPHON MANIFOLDED TANKS <br />CATEGORY : ANNULAR SPACE <br />VAPOR PROCESSOR TYPE <br />TO: NONE <br />VEEDER-ROOT POLISHER <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />L 6:DIESEL STP SUMP <br />ANALYSIS TIMES <br />TRI-STATE (SINGLE FLOAT) <br />TIME: 10:00 AM <br />LEAK MIN PERIODIC: 0% <br />CATEGORY : STP SUMP <br />DELAY MINUTES: 1 <br />0 -- <br />__LEAK <br />LEAK MIN ANNUAL 0% <br />OUTPUT RELAY SETUP <br />0 <br />- - - - - - - - - - - - <br />R 1:87 <br />PERIODIC TEST TYPE <br />TYPE: <br />STANDARD <br />STANDARD <br />NORMALLY CLOSED <br />ANNUAL TEST FAIL <br />SOFTWARE REVISION LEVEL <br />ALARM DISABLED <br />LIQUID SENSOR ALMS <br />VERSION 329.01 <br />SOFTWARE# 346329-100-B <br />PERIODIC TEST FAIL <br />L 4:FUEL ALARML <br />CREATED - 09.01.29.15.44 <br />ALARM DISABLED <br />4:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />NO SOFTWARE MODULE <br />GROSS TEST FAIL <br />R 2:RED DIESEL <br />SYSTEM FEATURES: <br />ALARM DISABLED <br />TYPE: <br />PERIODIC IN -TANK TESTS <br />STANDARD <br />ANNUAL IN -TANK TESTS <br />ANN TEST AVERAGING: OFF <br />NORMALLY CLOSED <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />LIQUID SENSOR ALMS <br />TNK TST SIPHON BREAKOFF <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />DELIVERY DELAY 5 MIN <br />L 2:SHORT ALARM <br />PUMP THRESHOLD 10.00% <br />R 3:DIESEL <br />TYPE: <br />LEAK TEST METHOD <br />STANDARD <br />- - - - - - - - - - - - <br />NORMALLY CLOSED <br />TEST ON DATE : ALL TANK <br />OCT 10, 2003 <br />START TIME : DISABLED <br />LIQUID SENSOR ALMS <br />TEST RATE :0.20 GAL/HR <br />L 6:FUEL ALARM <br />DURATION 2 HOURS <br />L 6:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />TST EARLY STOP:DISABLED <br />LEAK TEST REPORT FORMAT <br />NORMAL <br />0 2013 Walton Engineering, Inc. <br />