My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITRING SYSTEM CERTI ATION <br />MAKE / MODEL OF MONITORING SYSTEM: Gilbarco EMC <br />CERTIFICATION /TEST DATE: December 6. 2012 <br />Al. FACILITY <br />Name Olympian # 427 <br />Address 3300 Waterloo Road, Stockton, CA 95205 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A2. OWNER <br />Name Flyers Energy LLC. <br />Address 2360 Lindbergh Street, Auburn, CA 95602 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Tank #1 (Product): Gasoline - 87 <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />In -Tank Gauging Probe <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />November 27, 2012 <br />■ <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Jeff Wong <br />Model: 0794390420 <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Piping Sump / Trench Sensor(s) <br />Phone # <br />916-373-1166 <br />B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (check the appropriate boxes to Indicate equipment inspected/serviced) <br />81 - TANKS <br />B2: DISPENSERS1UDC's <br />Dispenser # : 1 <br />❑ Dispenser Containment Sensor(s) Model: _ <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />❑ <br />■ <br />■ <br />Tank #1 (Product): Gasoline - 87 <br />Tank #2 (Product): Red Diesel <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390-420 <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390420 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-208 <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-205 <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: FE Petro STP -MLD <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />Tank #3 (Product): Diesel <br />Tank #4 (Product): _ <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />❑ <br />In -Tank Gauging Probe <br />Model: <br />■ <br />Annular Space or Vault Sensor <br />Model: 0794390-420 <br />❑ <br />Annular Space or Vault Sensor <br />Model: <br />■ <br />Piping Sump / Trench Sensor(s) <br />Model: 0794380-205 <br />❑ <br />Piping Sump / Trench Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />❑ <br />Fill Sump Sensor(s) <br />Model: <br />■ <br />Mechanical Line Leak Detector <br />Model: VMI 99LD-2000 <br />❑ <br />Mechanical Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Electronic Line Leak Detector <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Tank Overfill / High -Level Sensor <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />❑ <br />Other (specify equipment in Section E) <br />Model: <br />B2: DISPENSERS1UDC's <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, i have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />•'- . \ Wit WALTON <br />Signature: oL 01 ENGINEERING, INC. <br />Technician / Cert #: Jessie Wadkins / B36391 5307886 -UT Date: December 6, 2012 <br />Dispenser # : 1 <br />❑ Dispenser Containment Sensor(s) Model: _ <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />❑ <br />■ <br />■ <br /># : 2 <br />Dispenser Containment Sensor(s) Model: <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 3-4 <br />❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser <br />❑ <br />■ <br />■ <br /># : 5 <br />Dispenser Containment Sensor(s) Model: <br />Shear Valves <br />Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 7 <br />❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />Dispenser # : 8 <br />❑ Dispenser Containment Sensor(s) Model: <br />■ Shear Valves <br />■ Dispenser Containment Float(s) and Chain(s) <br />C. CERTIFICATION I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. <br />Attached to this Certification Is Information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the <br />layout of monitoring equipment. For any equipment capable of generating such reports, i have also attached a copy of the report; (check all that apply): <br />■ System set-up ■ Alarm History Report <br />•'- . \ Wit WALTON <br />Signature: oL 01 ENGINEERING, INC. <br />Technician / Cert #: Jessie Wadkins / B36391 5307886 -UT Date: December 6, 2012 <br />