Laserfiche WebLink
LINE LEA ETECTOR (LLD) TEO REPORT <br />TEST DATE: December 6, 2012 <br />Al. FACILITY <br />Name Olympian # 427 <br />Address 3300 Waterloo Road, Stockton, CA 95205 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A2. OWNER <br />Name Flyers Energy LLC. <br />Address 2360 Lindbergh Street, Auburn, CA 95602 <br />Phone # 530-885-0401 <br />Contact Amanda Appelt <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />1 <br />Name <br />Walton Engineering, Inc. <br />Address <br />1868 E. Hazelton Avenue, Stockton, CA 95202 <br />Red Diesel <br />Address <br />P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />November 27, 2012 <br />MLLD <br />Lic # <br />617238 A, B, Haz <br />Inspector <br />Jeff Wong <br />VMI 99LD-2000 <br />Contact <br />Dulcinea Covan <br />Phone # <br />209-468-8257 <br />6101080 <br />Phone # <br />916-373-1166 <br />I. LINE LEAK DETECTOR TEST RESULTS I <br />Tact Fniiinmanf I lean• Vnnnrlacc \/MI I r1T_.Qan <br />J. COMMENTS: <br />w _ WALTON <br />Signature: 01 <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: December 6, 2012 <br />Tank number <br />Product contained <br />1 <br />2 <br />3 <br />Gasoline - 87 <br />Red Diesel <br />Diesel <br />Leak Detector Type <br />Leak detector make/model <br />MLLD <br />MLLD <br />MLLD <br />FE Petro STP -MLD <br />VMI 99LD-2000 <br />VMI 99LD-2000 <br />Serial number <br />2080784 <br />6071282 <br />6101080 <br />Functional Element Holding (psi) <br />18 <br />31 <br />31 <br />Resiliency (ml) <br />125 <br />3.00 <br />28 <br />60 <br />70 <br />Test leak rate (gph) <br />_ <br />3.00 <br />3.00 <br />Pump pressure (psi) <br />32 <br />31 <br />Metering pressure (psi) <br />10 <br />18 <br />19 <br />19 <br />Pressure Restriction Reduction (psi) <br />13 <br />12 <br />Length of Restriction Test (seconds) <br />30 <br />30 <br />30 <br />Full Flow Opening time (seconds) <br />6 <br />2 <br />2 <br />PASS <br />TEST RESULT <br />PASS <br />PASS <br />Tank number <br />Product contained <br />Leak Detector Type <br />Leak detector make/model <br />Serial number <br />Functional Element Holding (psi) <br />Resiliency (ml) <br />Test leak rate (gph) <br />Pump pressure (psi) <br />Metering pressure (psi) <br />Pressure Restriction Reduction (psi) <br />Length of Restriction Test (seconds) <br />Full Flow Opening time (seconds) <br />TEST RESULT <br />J. COMMENTS: <br />w _ WALTON <br />Signature: 01 <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: December 6, 2012 <br />