My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SYSTEM SET-UP REPOR <br />T 3:RED DIESEL <br />T 4:DIESEL <br />PRODUCT CODE <br />3 <br />PRODUCT CODE <br />4 <br />THERMAL COEFF <br />:.000450 <br />THERMAL COEFF <br />:.000450 <br />TANK DIAMETER <br />96.00 <br />TANK DIAMETER <br />96.00 <br />TANK PROFILE <br />I PT <br />TANK PROFILE <br />1 PT <br />FULL VOL <br />10000 <br />FULL VOL <br />12000 <br />FLOAT SIZE: 4.0 IN. <br />WATER WARNING 1.0 <br />HIGH WATER LIMIT: 2.0 <br />MAX OR LABEL VOL: 10000 <br />OVERFILL LIMIT 900 <br />9000 <br />HIGH PRODUCT 95% <br />9500 <br />DELIVERY LII°lIT 10% <br />1000 <br />LOW PRODUCT 1000 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED 'TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />T#: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />FLOAT SIZE: 3.0 IN. <br />WATER WARNING 1.0 <br />HIGH WATER LIMIT: 2.0 <br />MAX OR LABEL VOL: 12000 <br />OVERFIL.L LIMIT 90% <br />10800 <br />HIGH PRODUCT 95`•5 <br />11400 <br />DELIVERY LIMIT 10% <br />1200 <br />LOW PRODUCT 1000 <br />LEAK ALARM LIMIT: 99 <br />SUDDEN LOSS LIMIT: 99 <br />TANK TILT 0.00 <br />PROBE OFFSET 0.00 <br />SIPHON MANIFOLDED TANKS <br />T#: NONE <br />LINE MANIFOLDED TANKS <br />TO: NONE <br />LEAK MIN PERIODIC: 0% <br />0 <br />LEAK MIN ANNUAL 0% <br />0 <br />PERIODIC TEST TYPE PERIODI(' TEST TYPE <br />STANDARD STANDARD <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />EROS;; TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5 MIN <br />PUMP THRESHOLD 10.00% <br />0 2012 Walton Engineering, Inc. <br />ANNUAL TEST FAIL <br />ALARM DISABLED <br />PERIODIC TEST FAIL <br />ALARM DISABLED <br />GROSS 'TEST FAIL <br />ALARM DISABLED <br />ANN TEST AVERAGING: OFF <br />PER TEST AVERAGING: OFF <br />TANK TEST NOTIFY: OFF' <br />TNK TST SIPHON BREAKOFF <br />DELIVERY DELAY 5MIN <br />PUMP THRESHOLD 10.00% <br />LEAK TEST METHOD <br />TEST ON DATE : ALL TANK <br />OCT 10, 2003 <br />START TIME : DISABLED <br />TEST RATE :0.20 GAL/HR <br />DURATION : 2 HOURS <br />'TST EARLY STOP:DISABLED <br />LEAK TEST REPORTNFORMAT <br />(Page 2) <br />LIQUID SENSOR SETUP <br />L 1:RED DIESEL ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 2 : RED DIESEL, STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 3:87 ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 4:07 STP SUMP <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : STP SUMP <br />L 5:DIESEL. ANNULAR <br />TRI-STATE (SINGLE FLOAT) <br />CATEGORY : ANNULAR SPACE <br />L 6 : D I ESEL. STP SUMP <br />TRI-E;TATE (SINGLE FLOAT) <br />CATEC:ORY : STP SUMP <br />OUTPUT RELAY SETUP <br />R 1:07 <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIQUID SENSOR ALMS <br />L 4:FUEI. ALARM <br />L 4:SENSOR OUT ALARM <br />L 4:SHORT ALARM <br />R 2:RED DIESEL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIGU1D SENSOR ALMS <br />L 2:FUEL ALARM <br />L 2:SENSOR OUT ALARM <br />L 2:SHORT ALARM <br />R 3:DIESEL <br />TYPE: <br />STANDARD <br />NORMALLY CLOSED <br />LIGU1D SENSOR ALMS <br />L 6:FUEL ALARM <br />L 6:SENSOR OUT ALARM <br />L 6:SHORT ALARM <br />