My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
K. SPILL CONTAINER TEST RESULTS <br />measuring tquipment usea: Laiaweii aysiem zuu-I / vvanon <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (± 0.000 inches) <br />Pass/Fail threshold (0.005 inches /'/: Hr.) <br />TEST RESULT <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />13.50 <br />No <br />N/A <br />Dry <br />Entire <br />12.00 <br />0:05 <br />9:29 <br />9:59 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />2 <br />Red Diesel <br />5 <br />OPW <br />11.00 <br />No <br />N/A <br />Dry <br />Entire <br />9.50 <br />0:05 <br />10:13 <br />10:43 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />g kLevel t,nange Inaii <br />3 <br />Diesel <br />5 <br />OPW <br />15.00 <br />No <br />N/A <br />Dry <br />Entire <br />13.50 <br />0:05 <br />9:33 <br />10:03 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />I I <br />L. COMMENTS: <br />WALTON <br />Signature: aW�� 01 <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: December 1, 2011 <br />© 2011 Walton Engineering, Inc <br />ANNUAL WILL <br />CONTAINER TEN REPORT <br />TEST DATE: December 1, 2011 <br />Al. FACILITY <br />A2. OWNER <br />Name <br />Olympian # 427 <br />Name Flyers Energy LLC. <br />Address <br />3300 Waterloo Road, Stockton, CA 95205 <br />Address 2360 Lindbergh Street, Auburn, CA 95602 <br />Phone # <br />530-885-0401 <br />Phone # 530-885-0401 <br />Contact <br />Amanda Appelt <br />Contact Amanda Appelt <br />A3. C U P A <br />A4. TESTING CONTRACTOR <br />Name <br />San Joaquin County Environmental Health <br />Name Walton Engineering, Inc. <br />Address <br />600 E. Main Street, Stockton, CA 95202 <br />Address P.O. Box 1025, W. Sacramento, CA 95691 <br />Notified <br />November 22, 2011 <br />Lic # 617238 A, B, Haz <br />Inspector <br />Jeff Wong <br />Contact Dulcinea Covan <br />Phone # <br />209-468-8257 <br />Phone # 916-373-1166 <br />K. SPILL CONTAINER TEST RESULTS <br />measuring tquipment usea: Laiaweii aysiem zuu-I / vvanon <br />Tank Number <br />Product contained <br />Spill container capacity (US gallons) <br />Spill container manufacturer <br />Spill container depth (inches) <br />Is the spill container located in a sump? <br />Does sump have a liquid sensor installed? <br />Condition of spill container prior to testing <br />Portion of spill container tested <br />Depth of water level from bottom (inches) <br />Wait time for water level to stabilize (hr:min) <br />Test start time <br />Test end time <br />Test duration (hr:min) <br />Change in water level (± 0.000 inches) <br />Pass/Fail threshold (0.005 inches /'/: Hr.) <br />TEST RESULT <br />1 <br />Gasoline - 87 <br />5 <br />OPW <br />13.50 <br />No <br />N/A <br />Dry <br />Entire <br />12.00 <br />0:05 <br />9:29 <br />9:59 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />2 <br />Red Diesel <br />5 <br />OPW <br />11.00 <br />No <br />N/A <br />Dry <br />Entire <br />9.50 <br />0:05 <br />10:13 <br />10:43 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />g kLevel t,nange Inaii <br />3 <br />Diesel <br />5 <br />OPW <br />15.00 <br />No <br />N/A <br />Dry <br />Entire <br />13.50 <br />0:05 <br />9:33 <br />10:03 <br />0:30 <br />0.000 <br />0.005 <br />PASS <br />I I <br />L. COMMENTS: <br />WALTON <br />Signature: aW�� 01 <br />ENGINEERING, INC. <br />Technician: Jessie Wadkins / B35391 5307886 -UT Date: December 1, 2011 <br />© 2011 Walton Engineering, Inc <br />