My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
PRODUCT PIPING SUMP TESTING <br />Test Method By: O Manufacturer • Industry Standard o Professional Engr o Other (see below) <br />Test Method Uses: O Pressure O Vacuum • Hydrostatic o Other (see below) <br />Measuring Equipment Used: INCON TS -STS (Electronic Sump Test System) <br />Description Tank #2 Tank #3 Tank #d <br />Tank product <br />Gasoline - 87 <br />Red Diesel <br />Diesel <br />Sump material <br />FRP <br />FRP <br />FRP <br />Sump diameter (inches) <br />42 <br />42 <br />42 <br />Sump depth (inches) <br />48 <br />51 <br />46 <br />Height from tank top to highest <br />piping penetration (inches) <br />13 <br />13 <br />13 <br />Height from tank top to lowest <br />electrical penetration (inches) <br />11 <br />11 <br />11 <br />Method of sump attachment to tank <br />Tank Collar <br />Tank Collar <br />Tank Collar <br />Condition of sump prior to testing <br />Dry <br />Dry <br />Dry <br />Portion of sump tested <br />Entire <br />Entire <br />Entire <br />Is system programmed for fail-safe operation? <br />Unknown <br />Unknown <br />Unknown <br />Was fail-safe verified to be operational? <br />No <br />No <br />No <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Yes <br />Was sensor properly replaced after testing? <br />Yes <br />Yes <br />Yes <br />Depth of water level from tank top (inches) <br />15 <br />16 <br />15 <br />Wait time for water level to stabilize (hr:min) <br />0:05 <br />0:05 <br />0:05 <br />Test start time <br />12:31 PM <br />11:50 AM <br />12:08 PM <br />Initial Probe Reading <br />4.9340 <br />2.0227 <br />4.8306 <br />Test end time <br />12:46 PM <br />12:05 PM <br />12:23 PM <br />Final Probe Reading <br />4.9333 <br />2.0222 <br />4.8310 <br />Test duration (hr:min) <br />0:15 <br />0:15 <br />0:15 <br />Change in water level (± 0.0000 inches) <br />-0.0007 <br />-0.0005 <br />0.0004 <br />Pass/Fail threshold (±0.0020 inches /; Hr.) <br />0.0020 <br />0.0020 <br />0.0020 <br />TEST RESULT <br />PASS <br />PASS <br />PASS <br />Comments: <br />0 2011 Walton Engineering, Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.