My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
San Joaquin County lqw <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sjgov.or./q ehd <br /> 10i=111 <br /> Facility Name: Facility Address: Date: <br /> Nella Oil#427 3300 Waterloo Rd Stockton December 17 2015 <br /> i MINOR <br /> Item# Remarks <br /> 106 CCR 2632 Monitoring and response plans not current or approved by the EHD. <br /> The monitoring plan is not current and/or not approved by the EHD. Upon field verification, the monitoring plan for the <br /> diesel tank(427-03) is inaccurate. Diesel tank(427-03) listed the leak sensor model as 208, when verified in the field <br /> that the leak sensor model was 205 and diesel tank(427-03) line leak detector is listed as FE Petro STP MLD when <br /> verified that the diesel line leak detector is a VMI 99LD-2000. The monitoring plan must be uploaded to the California <br /> Environmental Reporting System (CERS). Immediately log into CERS, make the necessary changes, and submit for <br /> review by the EHD. <br /> This is a minor violation. <br /> 204 CCR 2712(1) Current monitoring plan approved by the EHD not found on site. <br /> An approved copy of the monitoring plans and response plan were not available for inspection. A copy of these plans <br /> shall be accessible on site at all times. Immediately locate and retain a copy on site. <br /> This is a minor violation. <br /> 307 CCR 2632(c) Monitoring system of the interstitial space of a double walled system not maintained. <br /> The 87 annular sensor failed to activate an audible and visual alarm when tested and, therefore, the tank is not <br /> monitored. The interstitial space shall be monitored with a monitoring system connected to an audible and visual <br /> alarm system. The technician cleaned the 87 annular sensor, retested and it passed. This was corrected on site. <br /> This is a Class II violation. <br /> 309 CCR 2636(f)(1) Monitoring in the UDCs failed to activate an audible and visual alarm or stop the flow at the UDC. <br /> The Bravo box float and chains in all UDC sumps failed to stop the flow of product at the dispenser when tested. All <br /> monitoring equipment shall be maintained to activate an audible and visual alarm or stop the flow of product at the <br /> dispenser when it detects a leak. The service technician adjusted the chains, verified functionality and they passed. <br /> This was corrected on site. <br /> This is a repeat violation, Class II. <br /> Overall Inspection Comments: <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, by January 16, 2016. <br /> Please be aware that as of January 1, 2014, facility operators are required to upload the following UST program <br /> documents into the California Environmental Reporting System (CERS): UST Monitoring Site Plan, UST <br /> Certification of Financial Responsibility, UST Response Plan, UST Letter from Chief Financial Officer (if <br /> applicable), and the Owner Statement of Designated Operator Compliance. The UST Owner/Operator: Written <br /> Agreement, if applicable, can be stored at the facility or uploaded into CERS. <br /> Received by Inspector: Phone: Date: <br /> (initial): � "NoP CINDY VO, EH Specialist i (209)468-8257 12/17/2015 <br /> Page 4 of 5 <br />
The URL can be used to link to this page
Your browser does not support the video tag.