My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2011-2016
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
3300
>
2300 - Underground Storage Tank Program
>
PR0231765
>
COMPLIANCE INFO_2011-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 4:27:40 PM
Creation date
6/3/2020 9:52:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2011-2016
RECORD_ID
PR0231765
PE
2361
FACILITY_ID
FA0003600
FACILITY_NAME
Nella Oil #427
STREET_NUMBER
3300
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95205
CURRENT_STATUS
01
SITE_LOCATION
3300 Waterloo Rd
P_LOCATION
99
P_DISTRICT
002
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231765_3300 WATERLOO_2011-2016.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
370
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITCSING SYSTEM CERTI AT . Z'__ .1- L . <br /> MAKE/ MODEL OF MONITORING SYSTEM: Gilbarco EMC <br /> CERTIFICATION /TEST DATE: December 17, 2014 iE C 2 4 ?ii 14 <br /> A1. FACILITY A2. OWNER EN VIR0NN111E „T/"..'...{`E,A.LTH <br /> Name Flyers#427 Name Flyers Energy LLC. -I _r <br /> Address 3300 Waterloo Road,Stockton,CA 95205 Address 2360 Lindbergh Street,AL%LFM,'CX 95602 <br /> Phone# 530-885-0401 Phone# 530-885-0401 <br /> Contact Amanda Appelt contact Amanda Appelt <br /> A3. C U P A A4. TESTING CONTRACTOR <br /> Name San Joaquin County Environmental Health Name Walton Engineering, Inc. <br /> Address 1868 E.Hazelton Avenue,Stockton,CA 95202 Address P.O.Box 1025,W.Sacramento,CA 95691 <br /> Notified December 8,2014 Lic# 617238 A,B,Haz <br /> Inspector Jeff Wong Contact Veronica Freitas <br /> Phone# 209-468-8257 Phone# 916-373-1166 <br /> B. INVENTORY OF EQUIPMENT TESTED/CERTIFIED (Check the appropriate boxes to indicate equipment inspected/serviced) <br /> 131: TANKS <br /> Tank#1 (Product): Gasoline-87 Tank#2 (Product): Red Diesel <br /> ❑ in-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ■ Annular Space or Vault Sensor Model: 0794390-420 <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-208 ■ Piping Sump/Trench Sensor(s) Model: 0794380-20_5 <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: FE Petro STP-MLD ■ Mechanical Line Leak Detector Model: VMI 99LD-2000 <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: I ❑ Other (specify equipment in Section E) Model: <br /> Tank#3 (Product): Diesel Tank#4 (Product): <br /> ❑ In-Tank Gauging Probe Model: ❑ In-Tank Gauging Probe Model: <br /> ■ Annular Space or Vault Sensor Model: 0794390-420 ❑ Annular Space or Vault Sensor Model: <br /> ■ Piping Sump/Trench Sensor(s) Model: 0794380-205 ❑ Piping Sump/Trench Sensor(s) Model: <br /> ❑ Fill Sump Sensor(s) Model: ❑ Fill Sump Sensor(s) Model: <br /> ■ Mechanical Line Leak Detector Model: VMI 99LD-2000 ❑ Mechanical Line Leak Detector Model: <br /> ❑ Electronic Line Leak Detector Model: ❑ Electronic Line Leak Detector Model: <br /> ❑ Tank Overfill/High-Level Sensor Model: ❑ Tank Overfill/High-Level Sensor Model: <br /> ❑ Other (specify equipment in Section E) Model: ❑ Other (specify equipment in Section E) Model: <br /> 62: DISPENSERS/UDC's <br /> Dispenser#: 1 Dispenser#: 2 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chain(s) <br /> Dispenser#: 3-4 Dispenser#: 5 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chains) <br /> Dispenser#: 6 Dispenser#: 7 <br /> ❑ Dispenser Containment Sensor(s) Model: ❑ Dispenser Containment Sensor(s) Model: <br /> ■ Shear Valves ■ Shear Valves <br /> ■ Dispenser Containment Float(s)and Chain(s) ■ Dispenser Containment Float(s)and Chains) <br /> C. CERTIFICATION I certify that the equipment Identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the <br /> layout of monitoring equipment. For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply): <br /> ■ System set-up ■ Alarm History Report <br /> 1-- WA WALTON <br /> Signature: aV°du ENGINEERING,INC. <br /> Technician/Cert#: Jessie Wadkins 1835391 5307886-UT Date: December 17,2014 <br /> LZ 2014 Walton Engineering,Inc. <br />
The URL can be used to link to this page
Your browser does not support the video tag.