COMPLIANCE INFO_1997-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 3:52:47 PM
Creation date
6/3/2020 9:53:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
DOUBLE CONTAINED PIPING <br />INTERSTITIAL SPACE MONITOR: X LIQUID <br />SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS -350 Dual Float Discriminating Series 794380-352 <br />EQUIPMENT AT THIS FACILITY IS: Veeder-Root TLS -350 PLLD Series 848480-001 <br />All double contained piping is continuously monitored electronically by a system that can sense a leak at <br />of 3 gallons or more per hour at 10 lbs. per square inch of line pressure within 1 hour at more than one <br />location with positive shut down. If the pressure sensor is activated, the line pressure monitor is <br />capable of sensing the pressure loss in the system and disables the flow of product through the lines. <br />All product lines are sloped down towards the tank, and any liquid in the annular space will flow <br />backwards into the sump area. There is a sensor in the sump area that detects any liquid present there. <br />The system has both visible and audible alarms that are activated when there is liquid in the sump or <br />detected in the secondary containment. At least annually, the system is capable of detecting a release <br />from the primary piping equivalent to .1 gph defined at 150% operating pressure. <br />RESPONSE PLAN <br />If the system goes into the alarm mode, the Operator or his designate will check the alarm panel to verify <br />that there is a leak condition and then silence the audible alarm. The Operator or his designee will <br />immediately contact Chevron dispatch and advise them of the situation so that they can contact the <br />appropriate personnel who will follow the instructions outlined in the "Leak Response Plan", which is part <br />of your Hazardous Material Management Plan. All follow up will be completed within the month the <br />problem occurred. <br />DISPENSER CONTAINMENT <br />SUMP MONITOR: X LIQUID SENSOR Veeder-Root TLS -350 Single Float Series 794390-208 <br />All dispensers are double contained with fiberglass pans that are continuously monitored electronically <br />using liquid sensors. The system has both visible and audible alarms that are activated when liquid is <br />detected. <br />The monitoring system will be inspected daily. The Operator or an employee appointed by the Operator <br />will follow the same procedures as outlined for monitoring the double contained product tanks. <br />PREVENTATIVE MAINTENANCE <br />The monitoring equipment shall be inspected and certified annually. Maintenance will be performed <br />annually or as needed. All work performed to the monitoring system will be in accordance to the <br />manufacturers recommendations. <br />TRAINING <br />Tank operators are trained on the proper operations of the monitoring equipment per the manufacturer's <br />instructions. <br />Chevron Emergency Information Center (CEIC)1-800-231-0623 <br />Chevron Maintenance Dispatch 1-800-423-3528 <br />4 <br />