My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_1997-2006
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_1997-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/20/2023 3:52:47 PM
Creation date
6/3/2020 9:53:03 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1997-2006
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_1997-2006.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
535
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
INSTRUCTIONS FOR COMP INCA FORM "B" <br /> GENERAL INSTRUCTIONS <br /> Section 2711 of Title 23, Division 3, Chapter 16, California Code of Regulations and sections 252.86, 25287, and 25289 <br /> of Chapter 6.7, Division 20, Health and Safety Code require tank owners to apply for an UST operating permit. <br /> 1. One FORM "R"shall be completed for each tank for all NEW PERMITS, PERMIT CHANGES, REMOV- <br /> ALS and/or any other TANK INFORMATION CHANGE. <br /> 2. This form should be completed by either the PERMIT APPLICANT or the LOCAL AGENCY UNDER- <br /> GROUNDTANK INSPECTOR. <br /> 3. Please type or print clearly all requested information. <br /> 4. Use a hard point writing instrument,you are croaking 3 copies. <br /> 5. Tank owners mast submit a plot plan to the local agency showing the location of the UST's with aspect <br /> to buildings and landmarks[2711 (a)(8)CCR]. <br /> 6, Tank owners roust submit documentation showing compliance with state financial responsibility require- <br /> ments to the local agency for petroleum USTs[2.711 (a)(11) CCR]. <br /> TOP OF FORM; MARK ONLY ONE ITEM <br /> 1. Mark an (X) in the box next to-the item that best describes the reason the form is being completed.r <br /> 2. Indicate the LEA or Facility nani'e where the tank iis,installed. <br /> 1. TANK DESCRIPTION - COMPLETE ALL ITEMS - IF UNKNOWN - SO SPECIFY <br /> A. Indicate owners tank 17 - If there is a tank number that is used by the owner to identify the tank(ex. <br /> AS7078 ). <br /> B3 Indicate the name of the company that manufactured the tank(ex. ACME TANK MFG). <br /> C. indicate the year the tank was installed (ex. 1987). <br /> C. Indicate the tank capacity in gallons (ex.25,000 or 10,000 etc.). <br /> II. TANK CONTENTS <br /> A. 1. IF MOTOR VEHICLE FUEL, check box 1 and complete items R&C. <br /> 2. If not MOTOR VEHICLE FUEL,check the appropriate box in section A and complete items S&D. <br /> B. Check the appropriate box. <br /> C. Check the type of MOTOR VEHICLE FUEL(if box 1 is checked in A). <br /> D. Print the chemical name of the hazardous substance stored in tree tank and the C.A.S.#. (Chemical <br /> Abstract Service number), if box 1 is NOT checked in A. <br /> Ill. TANK CONSTRUCTION -.MARK ONE ITEM ONLY IN SOX A, R, C & C} <br /> Check only one item in TYPE OF SYSTEM,TANK MATERIAL, INTERIOR LINING and CORROSION <br /> PROTECTION. <br /> if OTHER, print in the space provided. <br /> IV. PIPING INFORMATION <br /> 1. Circle"A" if above ground circle"U" if undergrounds and circle'bioth if applicable. <br /> 2. If UNKNOWN circle; or if OTHER, print in space provided. <br /> 3. indicate the LEAK DETECTION system(s) used to comply with the monitoring requirement for the piping. <br /> V. TANK LEAK DETECTION <br /> 1. Indicate the LEAD DETECTION systems)used to comply with the monitoring requirern is for the tank. <br /> V1, INFORMATION ON TANK PERMANENTLY CLOSED IN PLACE <br /> 1. ESTIMATED DATE LAST USED-MONTHNEAR (January, 1988 or 61/88) <br /> 2. ESTIMATED ED QUANTITY of HAZARDOUS SUBSTANCE remaining in the tank (in Gallons). <br /> 3. WAS TANK FILLED WITH INERT MATERIAL? Check"Yes"or"No" <br /> TANK OWNER OR AUTHORIZED REPRESENTATIVE MUST SIGN AND DATE THE FORM AS INDI- <br /> CATED [see section 2711 (a)(13) CCR) <br /> INSTRUCTION FOR THE LOCAL AGENCIES <br /> The state underground storage tank identification nurhber,is composed of the two digit county roam er, the` hr.ee digit <br /> jurisdiction member,the six digit facility number and the six digit tank number'. The county and jurisdiction numbers are <br /> predetermined and can be obtained by calling the State Board(916)227-4303. The facility number must be the same as <br /> shown in form "A". The tank number may be assigned by the local agency,however,this number must be numerical and <br /> cannot contain an alphabet. If the local agency prefers the State Board to assign the tank number, please leave it blank. <br /> IT IS THE RESPONSIBILITY OF THE LOCAL AGENCY THAT INSPECTS THE FACILITY TO VERIFY THE ACCU- <br /> RACY OF THE INFORMATION, THE LOCAL AGENCY IS RESPONSIBLE FOR THE COMPLETION OF THE <br /> "LOCAL AGENCY USE ONLY" INFORMATION BOX. THE LOCAL. AGENCY SHOULD RETAIN THE ORIGINAL AND <br /> YELLOW COPIES. THE PINK COPY SHOULD BE RETAINED BY THE TANK OWNER. <br />
The URL can be used to link to this page
Your browser does not support the video tag.