My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Feb, 23. 2015 11 : 11AM No. 5147 P. 4 <br /> Page;,of <br /> 6. PIPJNG SUMP TESTING <br /> Test Method Developed By: ❑ Sump Manufacturer Industry Standard ❑Pr+ibWV <br /> ❑Other(Specih) <br /> Test Method Used: ❑Pressure El vacuum ®Hydrostat' 2015 <br /> ❑ Other(Specf&) <br /> Test Equipment Used: See attached testing procedures I Equipment ResolutiMVIR <br /> Sump# g 7 Sump# Sump# Sump# <br /> Sump Diameter: y gr <br /> Sump Depth: Z <br /> Sump Material&Manufacturer: <br /> Height from Tank Top to Top of <br /> Highest Piping Penetration: 12- <br /> Height from Tank Top to Lowest <br /> Electrical Penetration: 2G Z 9 <br /> Condition of sump prior to testing: 0 K v <br /> Portion of Sum Tested' Above highest Above highest Above highest Above highest <br /> Sump penetration penetration enetration penetration <br /> Does turbine shut down when <br /> sump sensor detects liquid(both ❑Yes❑No®NA ❑Yes❑No M NA ❑Yes❑No M NA ❑Yes❑No®NA <br /> product and water)?* <br /> Turbine shutdown response time <br /> Is system programmed for fail-safe ❑Yes❑No®NA ®yes❑No®NA ❑Yes❑No®NA ❑Yes❑No®NA <br /> shutdown?* <br /> Was fail-safe verified to be ❑Yes❑No M NA . ❑Yes❑No®NA ❑Yes❑No M NA ❑Yes❑No®NA <br /> operational?* <br /> Wait time between applying <br /> pressme/vacuun/water and starting 30 minutes 30 minutes 30 minutes 30 minutes <br /> test: <br /> Test Start Time: f -2 7 <br /> Initial Reading(R°): +y v L- 047 ,39 <br /> Test End Time: 1'2 1 Z 7- 12.122 <br /> Final Reading(RF): 11069 ,3 U 9 y Z <br /> Test Duration: 15 min 15 min 15 min 15 min <br /> Change in Reading(RF-R,): 0,0 1--;7 4v Z <br /> Pass/Fail Threshold or Criteria: 0,002 0.002 0.002 0.002 <br /> ')('e8t Result: ® PABS ❑Fail M TPass [jFail ❑ pass ❑fail ❑ pass ..❑Tail'. <br /> Was sensor removed for testing? M Yes❑No❑NA MYes❑No❑NA ®Yes❑No❑NA M Yes❑No❑NA <br /> Was sensor properly replaced and <br /> verified functional after testing? ®Yes ElNo❑NA MYes❑No❑NA ®Yes❑No❑NA ®Yes❑No❑NA <br /> Comments— (include information on repairs made prior to resting, and reeontrnended follow-up for failed tests) <br /> ' If the entire depth of the sump is not tested,specify how much was tested. If the answer to any of the questions indicated with an <br /> asterisk(*)is"NO"or"NA",the entire sump must be tested. (See SWRCB LG-160) <br /> Received Time Feb, 23. 2015 11 : 21AM No. 8179 <br />
The URL can be used to link to this page
Your browser does not support the video tag.