My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> JAN 9 ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton,California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:vtr+r�vy slpov orrttettd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION RE ,T <br /> Facility Chevron Facility <br /> Address: 4344 E Waterloo Road, Stockton IrJan 9, 2014 <br /> Facility Ttle: Phone: <br /> Contact: Evelyn Gomez Asst Manager 931-2186 <br /> Inspection <br /> Type: XRouane Xvionitanng system Certification _!Installation C Camplaint-Ip#: I Other: <br /> (Authority HSC 252891 <br /> Consent far: Xlnspectfan ri Sampting XPhotos Grunted by: Evelyn Gomel Title: Ass's Manager <br /> Monilor6. Overfill <br /> Panel: Veeder--Root TLS-350 Sys',em: xPressurized ❑suctlon UGMavity Prevention: Mezhanical tlAucibledvisual <br /> uT 5 6 <br /> ,.._-_------. _._._._._.____._._. -_ <br /> Product &7 octane 91 octane -------- ---------- <br /> ----------- ___._•_-_- <br /> Designated tccp. <br /> Operator: Edward Dahlgren Cote: B-28-14 Violations: XRIf-Release Detection I.-W-Release Prevention 7M3-Bcth <br /> On Site Serutca ICC Exp. tVtaan-ftcturer's <br /> Te chn cian Jarrod Burke Date: 4-30-15 Tramlag. Veeder Root 5-7-14 <br /> vim AvloNS <br /> C1 C2 M I Code Section HSC-Cal rorrEia Health and Safi Ie;CCR=Gal!omla Cie ct a stto,e <br /> Cf=Claris 1 violation;C2�Ceara 2 vlon;M=Minor a°mfatl�n <br /> File Review <br /> 1Q1 HSC 25284 No permit to operate <br /> 102 HSC 254€4 5 Annual operating fees not paid <br /> 103 HSC 26284(a)(3) No vrritten agreement between the person that the operating permit ryas issued to and the tank operator to <br /> monitor the tank system <br /> 104 IiSC 25292.2 Current financial responsibility documents not on file with the.En%dronnicintal Health Department(EHD) <br /> 105 X CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 1(}5 CCR 2532(6) Monitoring—Program(Monitoring&Response Plans)Is not current or approved by the F_76 <br /> 107 1 CCR 2&32(d)(1)(C) Plot planlslte map not submitted or falls to )rnpletely shout where monitoring is performed <br /> losI CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(t)least nati <br /> st TC—Ron <br /> not provided to the END at least 48 hours dor to conE�uuctin the test <br /> Monitoring equipment certification:(a)not perforated annually;(d)test report not submitted witf8n 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EH®at least 48 hours prior to Conducting an installation.repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(8) Annual lime leak detector test not performed tr611 <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(1)(4) Annual litre t' htness test not,perforTned if positive shutdown or fail safe not present tt611 <br /> 113 CCR 2715(a) Failed to inform the EHD of change of designated operator within 3t}days <br /> 114 CCR 2715(b) ?Designated operator does not possess a current ICC CA UST System Operator oertification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion-o the-repair pursuant to (M2) <br /> permit conditions <br /> ItsHSC 252625 Enhanced leak detection(ELD)testing not performed on a system located srrithin 1000'of public well,or <br /> failures not repaired and retested <br /> E117 CCR 2661 Permit to repair-BST system not obtained <br /> 118 HSC 25286(•) Operational permit not an-tended vvtien USF storage and/or monitor/ system chap eci <br /> 919 HSC 23298(6} Permit to temporarily close UST system not obtained <br /> 120 DISC 25298(c) Permit to dose UST s tem not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years.cathodic protection records for&%gars,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 206 CCR 2792(6) upgrades for the life of the tank. Monitoring records Include:(1)date and Im of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)fogs of oil readings of gauges or other monitoring <br /> equipment, round water elevations,or Other test results;(6)reSUItS of ftentoy readings and recontkltations <br /> 202 CCR 2712(!) Monitoring plan,response plan,and/or operating pemtit and all condfi}ons not onsite <br /> Unauthorized release that:(c)did not escape secorsdary contammentMd cleared up"Min eight hiours (MI) <br /> 203 CCR 2650 was not recorded:(a)escaped secondary containment,not cleared up after eight hours,or a sudden loss of <br /> ____ I r-,I — rodua was not re arted to the EHD within 24 haute <br /> Inapecor Recaa—ea W. <br /> Garrett Backus (209) 468-2986 <br /> EHD 23. 2 Rmu D4r1S/12 Pape 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.