My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2012-2015
EnvironmentalHealth
>
EHD Program Facility Records by Street Name
>
W
>
WATERLOO
>
4344
>
2300 - Underground Storage Tank Program
>
PR0231766
>
COMPLIANCE INFO_2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/25/2023 1:18:05 PM
Creation date
6/3/2020 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231766
PE
2361
FACILITY_ID
FA0003717
FACILITY_NAME
CHEVRON STATION #99840*
STREET_NUMBER
4344
Direction
E
STREET_NAME
WATERLOO
STREET_TYPE
Rd
City
Stockton
Zip
95215
APN
10102156
CURRENT_STATUS
01
SITE_LOCATION
4344 E Waterloo Rd
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231766_4344 E WATERLOO_2012-2015.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
330
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
�ae#IityJS'it <br /> CHEVRON STATION#99840* CERS ID <br /> 4344 E WATERLOO RD 10181341 <br /> STOCKTON,CA 95205 LIST Tank# <br /> ................................................................................................................................................................................................................................................................................................................................... _............................_. <br /> TA0507191 <br /> ._. <br /> lT2)....... <br /> pipe <br /> M,0nIt0dr*U.P.1IiJFc rmed Using the Faallawing Met (s# <br /> -Yes Continuous monitoring of Piping Secondary Containment <br /> ;Piping Secondary Containment Panel Manufacturer Leak Sensor Manufacturer <br /> ;Dry VEEDER-ROOT VEEDER-ROOT <br /> Panel Model# Leak Sensor Model 4 <br /> TLS-350 794380-208 <br /> Yes Leak Alarm Triggers Automatic Pump Shutdown <br /> Yds <br /> Failure/Disconnect Triggers Pump Shutdown <br /> Mechanical Line Leak Detector Performs 3 GPH Leak Test <br /> :MLLD Manufacturer MLLD Model <br /> :Yes Electronic Line Leak Detector Performs 3 GPH Leak Test <br /> :ELLD Manufacturer ELLD Programmed In-Line Testing ELLD Triggers Automatic Pump Shutdown <br /> 1/EEDER-ROOT Yes <br /> ELLD Model ELLD Failure/Disconnect Triggers Automatic Shutdown <br /> OLLD yes <br /> Pipeline integrity Testing Visual Pipeline Monitoring <br /> ;Pipeline integrity Testing Frequency Visual Pipeline Monitoring Frequency <br /> Suction Piping Meets Exemption Criteria <br /> No Regulated Piping Per Health and Safety Code,Division 20,Chapter 6.7 is Connected To The Tank System <br /> Cather Pipeline Monitoring <br /> �nder Dispenser Ccsntainment WDC Monificsring <br /> LDDC Monitoring _... ..... ..... .. Detection of Leak into UDC Triggers Audible and Visual Alarms. <br /> Continuous Yes <br /> E <br /> UDC Leak Alarm Triggers Automatic Pump Shutdown j <br /> .VDC Panel Manufacturer Yes I <br /> VEEDER-ROOT failure/Disconnection of UDC Monitoring System Triggers Automatic Pump Shutdown <br /> IUDC Panel Model# Yes <br /> TLS-350 UDC Monitoring Stops Flow of Product at Dispenser <br /> :UDC Leak Sensor Manufacturer Yes <br /> /EEDER-ROOT UDC Construction <br /> :UDC Leak Sensor Model Single-walled <br /> 794380-208 UDC Secondary Containment Monitoring <br /> Leak Within Secondary Containment of UDC Causes Audible and Visual Alarms <br /> �'2riOt1i6 SySL@fn Testing <br /> ELD Testing <br /> ;Yes Secondary Containment Testing <br /> :Yes 5 i€I BucketTestin <br /> p <br /> Printed on 1/20/2014 11:07 AM <br />
The URL can be used to link to this page
Your browser does not support the video tag.