Laserfiche WebLink
Appendix V1 <br /> (Copies of Monitoring System Certification form and UST Monitoring Plot Plan available at hftp-.//Www.gwrcb.c"a.gov,) <br /> MONITORING SYSTEM CERTIFICATION <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited:Chapter 6.7,Health and Safety Code; Chapter 16,Division 3, Title 23, California Code of <br /> Regulations <br /> This form must be used to document testing and servicing of monitoring equipment.A separate certification or report must be prepared for each monitoring <br /> system control panel by the technician who performs the work.A copy of this form must be provided to the tank system owner/operator.The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: CHEVRON#99840 Bldg. No.: <br /> Site Address: 4344 E WATERLOO RD@ 99 City: STOCKTON Zip: 95215 <br /> Facility Contact Person: MANAGER Contact Phone No.: 209-931-2186 <br /> Make/Model of Monitoring System: Veeder Root TLS-350 Date of Testing/Servicing: 1/9/2014 <br /> B.Inventory of Equipment Tested/Certified <br /> Check thea ro riate boxes to indicate specific equipment ins pected/serviced: <br /> Tank ID: TI-SUPREME Tank ID: T2-REG UNLEAD <br /> P, In-Tank Gauging Probe. Model: mag Wo In-Tank Gauging Probe. Model: mag <br /> V Annular Space or Vault Sensor. Model: 409 P7 Annular Space or Vault Sensor. Model: 409 <br /> We Piping sump/Trench Sensor(s). Model: 208 R Piping Sump/Trench Sensor(s). Model: 208 <br /> r Fill Sump Sensor(s). Model: r Fill Sump Sensor(s). Model: <br /> r Mechanical Line Leak Detector. Model: Mechanical Line Leak Detector. Model: <br /> rV Electronic Line Leak Detector. Model: Veeder Root PLLD r%7 Electronic Line Leak Detector. Model: Veeder Root PLLD <br /> r4o Tank Overfill/High-Level Sensor.Model: flapper rV Tank Overfill/High-Level Sensor.Model: flapper <br /> r— Other(specify equipment type and model in Section E on Pa e 2). r— Other(specify equipment type and model in Section E on Page 2). <br /> Tank ID: Tank ID: <br /> In-Tank Gauging Probe. Model: In-Tank Gauging Probe. Model: <br /> r Annular Space or Vault Sensor. Model: Annular Space or Vault Sensor. Model: <br /> r— Piping Sump/Trench Sensor(s). Model: Piping Sump/Trench Sensor(s). Model: <br /> r Fill Sump Sensor(s). Model: Fill Sump Sensor(s). Model: <br /> r— mechanical Line Leak Detector. Model: r Mechanical Line Leak Detector. Model: <br /> r Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> r— Tank Overfill/High-Level Sensor.Model: Tank Overfill/High-Level Sensor.Model: <br /> r Other(specify eguipment type and model in Section E on Page 2). r Other(specify equipment type and model in Section E on Page 2). <br /> Dispenser 1/2 Dispenser 3/4 <br /> ID: ID: <br /> Wo Dispenser Containment Sensor(s).Model: 208 ry Dispenser Containment Sensor(s).Model: 208 <br /> r1.7 Shear Valve(s). WO Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). [_ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser 5/6 Dispenser 7/8 <br /> ID: ID: <br /> P Dispenser Containment Sensor(s).Model: 208 r-7 Dispenser containment Sensor(s).Model: 208 <br /> W Shear Valve(s). R Shear Valve(s). <br /> I— Dispenser Containment Float(s)and Chain(s). r Dispenser containment Float(s)and Chain(s). <br /> Dispenser 9/10 Dispenser 11/12 <br /> ID: ID: <br /> r%7 Dispenser Containment Sensor(s).Model: 208 rV Dispenser Containment Sensor(s).Model: 208 <br /> W Shear Valve(s). W Shear Valve(s). <br /> r Dispenser Containment Float(s)and Chain(s). r Dispenser containment Float(s)and Chain(s). <br /> *If the facility contains more tanks or dispensers,copy this form.Include information for every tank and dispenser at the facility. <br /> C.Certification-I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines.Attached to <br /> this Certification is information(e.g.manufacturers'checklists)necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment.For any equipment capable of generating such reports,I have also attached a copy of the report; (check all that apply):r.—. System set- <br /> up r—Alarm history report <br /> Technician Name(print): Jarrod Cooke Signature: <br /> Certification No.: B35255 License.No.: 743160 Class W <br /> Testing Company Name: Tanknology Phone No.: (800)800-4633 <br /> Testing Company Address: 11000 N.MoPac Expressway Suite 500 Date of Testing/Servicing: 1/9/2014 <br /> Monitoring System Certification Page I of 3 12/07 <br />