Laserfiche WebLink
NEW UNDERGROUND STORAGE TANKS - PLAN ADDITION/CORRECTION SHEET <br />The following checked and/or underlined items are to be addressed on plans: <br />GENERAL <br />_O 1. Provide the name and address of the facility. Sgeef t Louer Rt T,+I� <br />oic -see teff- 4 Tr -N &n � <br />< 2 Provide the name, address, and phone numbers of the­�contractor(s), facility <br />owner(s), and operator(s). r.,k, r.yk7&.J A d R -11r.-s OK 5/111 <br />3. Provide Provide four complete sets of plans. (One to be retained by this office). <br />include specification sheets, equipment brochures, monitoring, and response <br />plans. <br />Gl< <br />4. Provide plans to scale in nonerasable blueprint. <br />CONSTRUCTION STANDARDS <br />dk 1. Location(s) and number of tanks. Set ;kRpn,fi- - lAfgt -9( s -,t ?/6 Al <br />0k, 2. Type of tank(s) to be installed. -rh t 64ar,irrP«JT ✓Qeke �f 7 4 <br />A. Steel clad with fiberglass reinforced plastic. X�gx da.',,, f3�/yr�ify� �%,ekef <br />1. 35,000 to 40,000 volt Holiday Test required before "s�tting" tank(s) <br />in ground., <br />B. Fiberglass <br />1. Striker plate dimensions and materials. <br />2. Striker plates under all accessible openings. <br />C.-Nonclad steel <br />1. Cathodic protection provided (including nuts, bolts, washers, etc.). <br />a. Approved by a corrosion engineer or NACE technician. <br />b. Document stating inspection method and frequency (Minimum semi- <br />annual inspection required). <br />D. Other types of tanks <br />1. Construction specification standards for durability. <br />L_3. Tank Capacity (List specific gallonage). 54tt+ Score w0�� <br />POL <br />c5 K_4. Contents to be stored in each tank (Be specific).d,P_.,e/i Ufa-_'9APd q <br />A. Verification of product compatability with the Pnk(s), piping, monitoring <br />devi Listtesting ing 9y or silicone sapproval.eI'-re kvve P"5z A) <br />9 or9anizationand <br />rwk_4 <br />QHS. Provide manufacturers written installation instructions. (Include all piping,��,�� <br />monitors, tp9Jn s, et�c7. o<< <br />SCf i7Y.lS O/GKPTIr%` � <br />Note - NFPA 30 Test required before covering tank and systems. NFPA 30 Test <br />is require on BOTH the Primary and Secondary containment systems. <br />Double walled tanks using pressure or vacuum testing to monitor annular <br />space are exempt from testing secondary container. <br />Note - NFPA 329 "Precision Test" required upon completion of installations. <br />One test result copy to be sent directly to this department from the <br />testing company. <br />