PE
2361
FACILITY_ID
FA0003957
FACILITY_NAME
AT&T California - UE020
STREET_NUMBER
124
Direction
W
STREET_NAME
ELM
STREET_TYPE
St
City
Lodi
Zip
95240
CURRENT_STATUS
01
SITE_LOCATION
124 W Elm St
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
SJGOV\rtan
Supplemental fields
FilePath
\MIGRATIONS\UST\UST_2361_PR0231866_124 W ELM_1986-2000.tif
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
360
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPTION 2A <br />ARTICLE 3, SECTION 2633/2634 <br />MOTOR VEHICLE FUELS ONLY <br />CIONS ciairTION <br />1. Requirements: <br />A. Approved tank construction material <br />B. Leak interception and detection system which complies with Article 3, <br />Section 2631(c). <br />C. Membrane liners must comply with Article 3, Section 2633(e), (1), (2), <br />(3), (4),C-5) and are only allowed for piping systems (Department Policy) <br />D. Demonstrate that the leak interception and detection systems protects <br />Mround water .from contamination (Article 3, Section 2633(f),_(1), (2), (3), <br />, (5), (6), (7). r that is <br />E. Pressurized piping systems must be installed with a leak detector <br />capable of automatically shutting off the product pumps. <br />1. Any single wall component "tank or piping" requires daily inventory <br />reconcilliation and annual precision tests as part of the monitoring <br />programs <br />F. Before covering, the tank(s) and system(s) must be tested to NFPA 30, <br />Standards. <br />G. Before use - the tank(s) and system(s) must be tested in accordance to <br />NFPA 329. <br />H. Provide soil profile of vadose zone if membrane liners are used. <br />W1 <br />ARTICLE 3, SECTION 2634 <br />MOTOR VEHICLE FUELS ONLY <br />MONITORING <br />1. Requirements (leak interception and detection system(s)). <br />A. Floor must be constructed on a firm base and sloped to a <br />B. Access casings must be installed in accordance to Article <br />2634 (c) (1 thru 6), (d) (1). <br />C. Submit written monitoring and response plan as stated in <br />Section 2634 (d) (1-3), 2634(e) (1-5). <br />D. Hard wiring of electronic monitoring systems is required. <br />E. Provide manufacturer's written installation instructions. <br />collection sump. <br />3, Section <br />Article 3, <br />
The URL can be used to link to this page
Your browser does not support the video tag.